4 SBF Reference
BaseStation
Number:
5949
"OnChange"
interval: block generated each time a differential correc-
tion message related to the base station coordi-
nates is received
The
BaseStation
block contains the ECEF coordinates of the base station the receiver
is currently connected to. This block helps users accessing the base station coordinates
via SBF instead of having to decode the specific differential correction message (see the
SBF block above).
The interpretation to give to the X, Y, Z ECEF coordinates is dependent on the value of
the
Source
field:
Value of Source Interpretation of X, Y, Z
0, 4 or 10
Coordinate of the L1 phase center
2 or 8
Antenna reference point
9
Proprietary
Parameter
Type Units
Do-Not-Use
Description
Sync1
c1
Block Header, see 4.1.1
Sync2
c1
u2
ID
u2
Length
u2
1
byte
u4
0.001
s
4294967295
Receiver time stamp, see 4.1.3
u2
1
week
65535
BaseStationID
u2
The base station ID
BaseType
u1
Base station type:
0: Fixed
1: Moving (reserved for future use)
255: Unknown
Source
u1
Source of the base station coordinates:
0:
RTCM 2.x (Msg 3)
2:
RTCM 2.x (Msg 24)
4:
CMR 2.x (Msg 1)
8:
RTCM 3.x (Msg 1005 or 1006)
9:
RTCMV (Msg 3)
10:
CMR+ (Type 2)
Datum
u1
255
Not applicable
Reserved
u1
Reserved for future use, to be ignored by decoding software
X
f8
1
m
Antenna X coordinate expressed in the datum specified by the
Datum
field
Y
f8
1
m
Antenna Y coordinate
Z
f8
1
m
Antenna Z coordinate
Padding
u1[..]
Padding bytes, see 4.1.5
438
Summary of Contents for PolaRx5TR
Page 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Page 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Page 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Page 237: ...3 Command Line Reference COM1 237 ...
Page 279: ...3 Command Line Reference COM1 279 ...
Page 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...