3 Command Line Reference
sirs
girs
setIPReceiveSettings
getIPReceiveSettings
Cd
Cd
Port
Mode
TCPAddress (40)
+ IPR1
+ IPR2
+ IPR3
all
0 . . . 65535
TCP2Way
UDP
0.0.0.0
RxControl: Communication > Network Settings > General
This command configures the "IP receive" ports (IPR).
When
Mode
is set to
TCP2Way
, the receiver connects to the specified port of a server of which
the IP address or hostname is provided in the
TCPAddress
argument. It then receives all data
sent by this server on that port. The TCP2Way connection is bidirectional, and it is possible
to send data to the server or to process commands from the server.
When
Mode
is set to
UDP
, the receiver listens for incoming UDP messages on its port identified
by the
Port
argument. In
UDP
mode, the
TCPAddress
argument is ignored. Note that, contrary
to the TCP connection, the UDP connection is unidirectional.
If
Port
is set to 0, the corresponding IPR connection is disabled.
This command is the counterpart of the
command.
configures the sender side of the communication, while
configures the receiver side.
When selecting a port number, make sure to avoid conflicts with other services (for example
select a different port than in the
setIPPortSettings
command).
Example
COM1>
sirs, IPR1, 28785, TCP2Way, 192.168.10.5<CR>
$R: sirs, IPR1, 28785, TCP2Way, 192.168.10.5
IPReceiveSettings, IPR1, 28785, TCP2Way, 192.168.10.5
COM1>
189
Summary of Contents for PolaRx5TR
Page 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Page 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Page 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Page 237: ...3 Command Line Reference COM1 237 ...
Page 279: ...3 Command Line Reference COM1 279 ...
Page 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...