CHAPTER 6. OTHER RECE
I
VER OPERAT
I
ONS
6.2.2 Output over Ethernet
SBF and NMEA data can be sent over an Ethernet connection from the AsteRx SB Sx .
Ethernet settings are explained in Section 8.4.
Step 1: Configure an IP connection on the AsteRx SB Sx
The Ethernet port settings can be con
fi
gured by selecting
IP Ports
from the
Communication
menu.
I
n the example shown in Figure 6-9, port 600 has been con
fi
gured as connection
I
PS1
in
TCP2Way
mode so data can be received as well as transmitted over the connection. When
choosing a port number avoid con
fl
icts with other applications such as the commands port
(28784), the webserver port (80), the FTP port (21) as well as the default NTR
I
P port (2101)
and the NTP port (123).
Note that a new
I
P port can also be con
fi
gured by followings the sequence of settings for
NMEA output described in
Step 2
.
Figure 6-9:
Con
fi
gure the TCP/
I
P server port setting for data output
35