DVR Firmware and Configuration Uploads
700-0190 R003
4–7
4.2.2. Uploading Configuration Files to DVR via vMax Web
To remotely install a configuration update, the configuration file (received from Seon or created and
saved from a DVR in your network) must be on a computer with network access to the DVR and with
Internet Explorer 8 (32 bit version) to access vMax Web.
To upload a configuration update on the DX-HD via vMax Web:
1. On a computer, copy the DVR configuration file.
2. Power up the DVR using the vehicle ignition.
3. Open Internet Explorer, and in the address bar, type in the DVR IP address.
The default IP address is http://169.254.1.1.
4. The vMax Web login screen appears.
5. At the login prompt, enter a user name and password to access the internet browser user interface.
User names and passwords are case sensitive.
• Default User name: Admin.
• Default Password: 11111111.
Figure 4-10
Login vMax Web
CAUTION: DVR Password Security
The default password is 11111111. For security purposes, Seon recommends that the user default login
and system settings passwords should be changed. Seon is not responsible if the password is lost or
forgotten.