TROUBLESHOOTING TIPS
Troubleshooting Tips
Malfunctions
Unit does not
start
Unit not cooling
or heating
(Cooling/ heating
models only)
room very well
while air flowing
out from the air
cond tioner
i
Cause
Power cut
Unit may have become unplugged.
Fuse may have blown.
Battery in Remote controller may
have been exhausted.
The time you have set with timer
is incorrect.
Wait for power to be restored.
Check that plug is securely in wall
receptacle.
Replace the fuse.
Replace the battery.
Wait or cancel timer setting.
Set temperature correctly. For
detailed method please refer to
"
"
Using remote control section.
Clean the air filter.
Close the doors or windows.
Clear obstructions away first, then
restart the unit.
Wait.
Inappropriate temperature
setting.
Air filter is blocked.
Doors or Windows are open.
Air inlet or outlet of indoor or
outdoor unit has been blocked.
Compressor 3 minutes
protection has been activated.
If the trouble has not been corrected, please contact a local dealer or the nearest customer
service center. Be sure to inform them of the detailed malfunctions and unit model.
Notes: Do not attempt to repair the unit yourself.
Always consult an authorised service provider.
What should be done?
7. Dripping water may generate on the surface of the indoor unit when cooling in a high
relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to
the maximum air outlet position and select HIGH fan speed.
8.
The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit
during heating operation. When the outdoor temperature falls, heat drawn in by the air
conditioner decreases accordingly. At the same time, heat loading of the air conditioner
increases due to larger difference between indoor and outdoor temperature. If a
comfortable temperature can't be achieved by the air conditioner, we suggest you use a
supplementary heating device.
9.
Power failure during operation will stop the unit completely.
For the unit without Auto-restart feature, when the power restores, the OPERATION indicator
on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the
remote controller. For the unit with Auto-restart feature, when the power restores, the unit
restarts automatically with all the previous settings preserved by the memory function.
For some models, the machine is special designed with Auto-restart function for the open angle
of the horizontal louver.Power failure during operation or pressing the ON/OFF button on the
remote controller will stop the unit completely.When the power restores or pressing the ON/OFF
button on the remote controller again,the unit restarts automatically with all the previous settings
including the open angle of the horizontal louver by the memory function.So we strongly suggest
that the open angle of the horizontal louver should not be set too small,in case the condensed
water forms and drops from the horizontal louver. Press the AUTO/COOL button under the
front panel and the open angle of the horizontal louver will be restored to the standard angle
when the condensed water forms on the horizontal louver.
10. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction.
Disconnect the unit with power and then re-connect the unit with power again. Push the
ON/OFF button on the remote controller to restart operation.
11.
The protection of outdoor low temperature can be activated only in the HEATING mode.
The unit will stop operating and display "P3" on the LCD window of the indoor unit when the
outdoor temperature is or lower than 5 F(-15 C) for one hour, but the indoor unit in this situation
can still receive the signal from the remote controller.The unit will restart automatically with all the
previous settings preserved by the memory function when the outdoor temperature is or higher
than 11 F(-12 C) for 10 minutes and the compressor stop operating for more than one hour, or
when the outdoor temperature is or higher than 41 F(5 C) for 10 minutes.
Heating mode (For cooling and heating models only)
Auto-restart function
The protection of outdoor low temperature(on some models)
O
O
O
O
O
O
OPERATION TIPS
14
Stop the air conditioner immediately if one of the following faults occur. Disconnect the
power and contact the nearest customer service center.
Trouble
Fuse blows frequently or circuit breaker trips frequently.
Other objects or water penetrate the air conditioner.
The remote controller won't work or works abnormally.
OPERATION/RUN indicator or other indicators continue flashing and
this flash can't be fixed by disconnecting the power, and then connect it in again.
If one of the following code appears on the display area :
E0,E1,E2,E3.....or P0,P1,P2,P3......