background image

Display Navigation Guide, TotalSense Series 

Page 6 of 19

 

154-0042-0B 

 

Parameter 

Description 

Selections 

Functionality 

Settings > 

Display> 

Screen 

Lock 

Lock out access 
to home screen 

and settings 

Enable 

Screen lock mode will initiate after 

60s

 of inactivity.  

Screen saver will be shown until device is unlocked by 
holding the up and down buttons for 

5s

.   

Disable 

(default) 

Display will show home screen when any button is 
pressed. 

Settings > 

Display> 

Screen 

Saver 

Choose what to 

display when 

inactive 

Off 

Display will turn off after 

60s

 if inactivity.  No screen saver 

will be displayed.  Screen will remain blank until any 
button is pushed.   

Air Quality Icon 

The AQ leaf icon will be displayed when inactive in either 
green, yellow, or red depending on

 Air Quality 

Thresholds.

 

Air Quality Msg 

(default) 

Good air quality (green), Fair air quality (yellow), or poor 
(red) air quality will be displayed when inactive based on 

 

Air Quality Thresholds.

 

CO2 reading 

Current CO2 reading will be displayed in PPM. 

Temp reading 

Current Temp reading will be displayed in either 

o

F or 

o

C.  

See 

Temp Settings.

 

RH reading 

Current RH reading will be displayed in %. 

PM 

PMx value will be displayed in center (µg/m

3

).  Choose 

particle size in 

PM

 

Settings

Readings over 999 will be 

shown as mg/m

3

TVOC PPB 

Current TVOC reading will be displayed in center (PPB). 

TVOC µg/m

3

 

Current TVOC reading will be displayed in center (µg/m

3

).  

Readings over 999 will be shown as mg/m

3

Home 

Readings 

Display will cycle through all present sensor readings that 
are chosen to be displayed on the main screen.  See 
parameters: Center, Upper right, Lower Left, and Lower 
Right. 

All Readings 

Display will cycle through all present sensor readings 
from this list: temp, RH, CO2, TVOC, PM, and Air Quality. 

Settings > 

Display> 

Menu 

Brightness 

Adjust brightness 

of screen 

Low, medium, 

high 

(default: high) 

Adjust value to increase or decrease brightness of home 
screen and menu display. 

Settings > 

Display> 

SS 

Brightness

 

Adjust brightness 

of screen saver 

Low, medium, 

high (default: 

low) 

Adjust value to increase or decrease brightness of screen 
saver. 

 

Summary of Contents for TotalSense Series

Page 1: ...54 0042 0B Rev Release Date By Description of Change ECR 0A NAK Initial Release 0B 6 10 2022 NJS Updates for engineering CI release Copyright 2022 All rights reserved This document contains Senva Sens...

Page 2: ...ttings 10 PM Settings 10 RH Settings 11 Temp Settings 11 TVOC Settings 12 Slider Settings 12 Relay Settings 13 PIR Settings 14 Advanced Settings Diagnostics 15 Advanced Settings 15 Diagnostics 15 Air...

Page 3: ...he up and down arrows for 5 seconds to unlock Figure 1 Default Home Display Figure 2 Sample Display If you see a lock icon hold the up and down arrows for 5 seconds to unlock To change any setting pre...

Page 4: ...set each digit individually and press enter to move cursor to the left When all digits are set the value will be saved when enter is pressed again To view comms navigate to view comms in the main men...

Page 5: ...size in PM Settings Readings over 999 will be shown as mg m3 Slider Setpoint Value corresponding to position of slider set point will be displayed in center Slider range can be adjusted in Slider Set...

Page 6: ...2 reading Current CO2 reading will be displayed in PPM Temp reading Current Temp reading will be displayed in either o F or o C See Temp Settings RH reading Current RH reading will be displayed in PM...

Page 7: ...int as the baseline adjust this setpoint in Temp Settings PID CO2 Sets the output to a PID controller using the CO2 setpoint as the baseline adjust this setpoint in CO2 Settings PID Temp Set Point Set...

Page 8: ...re decreases Settings Analog Output 1 PID KP Proportional Coefficient 0 100 default 0 Sets the Proportional gain PID Coefficient Settings Analog Output 1 PID Ki Integral Coefficient 0 100 default 0 Se...

Page 9: ...isabled Settings Air Quality Use PM Use PM in the Air Quality calculation Enabled Disabled Settings Air Quality Use VOC Use VOC in the Air Quality calculation Enabled Disabled Air Quality Settings Goo...

Page 10: ...Disable Enable ABC Enable default Disable default if dual channel CO2 is selected Enable or disable ABC function for CO2 sensor calibration It is not recommended to disable this unless you are using...

Page 11: ...as PM selected as a source in Analog Parameters RH Settings Parameter Description Selections Functionality RH Settings Offset RH offset 5 to 5 default 0 Adjust RH reading by up to 5 RH Settings Analog...

Page 12: ...5000 g m3 default 0 g m3 This value corresponds to the lowest point on an analog scale for a TVOC reading This will correspond to any analog output that has TVOC selected as a source Analog Parameter...

Page 13: ...100 00 default depends on source selection Based on full scale range of the selected sensor set the value above which the relay will activate For example if CO2 is selected its full available range is...

Page 14: ...when this time has expired AND the turn off threshold is met Relay Settings Min Off Min off time 1 240s default 3s When relay de activates it will not activate again until this time has lapsed regard...

Page 15: ...sult factory 00000010 EEPROM data corruption Consult factory 00000100 EEPROM write error Consult factory 00001000 Device is currently using factory defaults Reset to factory defaults Consult factory 0...

Page 16: ...is will display several possible statuses in binary All zeros indicate no errors or warnings are present 00000001 Sensor hardware I2C fault Consult factory 00000010 Sensor error bad initialization ran...

Page 17: ...nsor Data Error Consult factory 00000100 Sensor not ready Consult factory 00001000 Sensor fan speed warning Warning only No action necessary 00010000 Sensor fan failure Consult factory 00100000 Sensor...

Page 18: ...000 g m3 3000 g m3 CO2 1200 PPM 1200 2000 PPM 2000 PPM Temp 64 79F 64 79F RH 30 60 30 60 10 90 The average air quality is calculated as follows for the sensors that have been enabled see Air Quality s...

Page 19: ...ale factor 1 218 Data Source http aqt vru com emissions complete list of vocs Contamination Name Molecular Weight Scale factor ACETYLENE ACETYLEN 26 04 0 565 FORMALDEHYDE FORMALD 30 03 0 652 METHANOL...