Sentry Saf-T-Vise STV-HP1 Installation, Operation & Maintenance Manual Download Page 13

Saf-T-Vise STV-HP1 and STV-HP3 13

Customer Support

With proven sampling expertise since 1924, Sentry products and services provide business operations the critical 

insights to optimize process control and product quality  We deliver true representative sampling and analysis 

techniques to customers around the globe, empowering them to accurately monitor and measure processes for 

improved production effi  ciency, output, and safety  Standing behind our commitments, we are determined to tackle 

any application, anywhere 

We know that running an effi  cient operation isn’t easy  It requires thorough, careful analysis of controlled, real-

time data achieved through reliable, accurate, and repeatable process monitoring, and measuring  By eff ectively 

conditioning, sampling, and measuring gas, liquid, slurry, powder, solids, steam, or water within their production 

environments, our customers obtain the critical insights they need to control and optimize their processes 

Yet, controlling your processes also means reliable customer support throughout the life cycle of your equipment 

 

ƒ

Customer Service—General information, warranty claims, order management 

 

ƒ

Installation Service—For systems that require specialized expertise upon installation 

 

ƒ

Technical Support—Troubleshooting, training, and technical manuals 

 

ƒ

Field Service & Retrofi ts—When a problem needs immediate attention 

 

ƒ

Replacements Parts & Consumables—Order your replacement parts and consumables 

 

ƒ

Sentry ProShield Services—Select from four ProShield Guardian service plans providing diff erent levels of support to 

protect your large system investments with regularly scheduled maintenance 

To learn more, go to 

www sentry-equip com/support

 

Summary of Contents for Saf-T-Vise STV-HP1

Page 1: ...Original Instructions Installation Operation Maintenance Manual Saf T Vise STV HP1 and STV HP3 Insertable Tool Holders S CM IOM 00506 3 03 22...

Page 2: ...ability Sentry Equipment Corp its employees agents and the authors and contributors to this document specifically disclaim all liabilities and warranties express or implied including warranties of mer...

Page 3: ...V HP3 Insertable Tool Holder Specifications 6 Installation and Operation 6 Maintenance 7 Inspecting the Safety Cap 7 Prepping the Tool Holder for Reinstallation 7 Cleaning the Rod Probe Shaft 7 Changi...

Page 4: ...ons DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious inj...

Page 5: ...ing with any chemical Read the product label and Material Safety Data Sheets MSDS carefully and follow the instructions exactly Potential Equipment Hazards Hot surfaces This equipment may have very ho...

Page 6: ...wable operating pressure MAP of 5 000 psi at 100 F 344 7 bar at 38 C for the STV HP1 and 7 500 psi at 100 F 517 1 bar at 38 C for the STV HP3 NOTE Flanged units have a MAP based on the class of flange...

Page 7: ...d anti seize lubricant to the holder threads Cleaning the Rod Probe Shaft The rod probe shaft should be cleaned each time the tool holder is removed from the line This helps prevent buildup on the rod...

Page 8: ...arrow at the top of the shaft Use a medium crescent wrench to loosen the adapter lock nut Remove both the adapter and the lock nut Atomizer shaft or quill shaft With a permanent marker mark the rod t...

Page 9: ...For Teflon seal Tighten the upper body until it is snug against the lower body Tighten set screw For graphoil seal Do not tighten the set screw until after installation of the rod shaft Thread but do...

Page 10: ...mount of anti seize lubricant to the shaft end take special care not to get any anti seize lubricant in the shaft as this could clog your nozzle tip b Thread the fluid adapter onto the shaft and tight...

Page 11: ...eaking from the top of the holder body where the rod shaft and body meet the graphoil seal is most likely loose 1 Adjust the top body to tighten the seal a Loosen the small set screw on the upper body...

Page 12: ...ard the top of the holder and then reinstall the locking collet bolt 2 Check the collet for wear A worn collet will not distribute pressure evenly on the rod shaft and may cause damage If the collet i...

Page 13: ...conditioning sampling and measuring gas liquid slurry powder solids steam or water within their production environments our customers obtain the critical insights they need to control and optimize the...

Page 14: ...14 Sentry Equipment Corp This page is intentionally left blank...

Page 15: ...Saf T Vise STV HP1 and STV HP3 15 This page is intentionally left blank...

Page 16: ...sentry equip com 966 Blue Ribbon Circle North Oconomowoc WI 53066 U S A 1 262 567 7256 support sentry equip com Serving customers in more than 50 countries across six continents worldwide...

Reviews: