e. 

Once the rod/shaft is through the body of the holder, reinstall the locking collet (if removed) with the orientation 

dot facing the top of the tool, and tighten the collet 

f. 

Remove the protective Teflon tape from the rod/shaft 

g. 

For atomizer or quill shaft only, reapply new Teflon tape (2–3 wraps is adequate)  Coupon holder rods do not 

need Teflon tape 

6. 

Finish reassembly 

For coupon holder rods only

a. 

Move rod/shaft through tool so the last 1 5 inches are visible out the top of the holder 

b. 

Tighten the locking collet bolt to 35 ft-lb (47 45 Nm) 

c. 

Reinstall the adapter and lock nut securely on the rod 

d. 

If using a graphoil seal, gently tighten the upper body onto the lower body, and then tighten the set screw 

 

Â

NOTE

If using graphoil seal, do not overtighten the upper body . This will make the rod/shaft difficult to move and cause 

excessive wear on the seal .

e. 

The tool is now ready to go back into service 

For atomizer or quill shafts 

a. 

Add a very small amount of anti-seize lubricant to the shaft end (take special care not to get any anti-seize 

lubricant in the shaft as this could clog your nozzle tip) 

b. 

Thread the fluid adapter onto the shaft and tighten the adapter using the small ¼" nipple (or multi-port valve) if 

no wrench flats are present  

c. 

If re-installing a used shaft, tighten down to the mark made earlier   

If installing a new shaft, align the mark on the fluid adapter with the outlet of the atomizer tip or quill  

d. 

If using graphoil a seal, gently tighten the upper body onto the lower body, and then tighten the set screw 

e. 

The tool is now ready to go back into service 

Changing a Coupon/Checking Probe End

Tools needed

 

ƒ

Clean rag

 

ƒ

Cleaner/solvent

 

ƒ

320 grit sand paper or other finer grit paper 

 

ƒ

Medium crescent wrench

 

ƒ

Molykote 55 lubricant or other fine viscosity lubricant

 

ƒ

Flat tip screwdriver

1. 

Remove tool holder from the process pipeline by following instructions for specific insertion tool  

2. 

Remove old coupon or inspect the rod/shaft as needed  

3. 

Clean the rod/probe shaft  

4. 

If using a coupon holder, attach the new coupon  

5. 

Reinstall the tool holder into the pipeline by following instructions for specific insertion tool 

Summary of Contents for Saf-T-Vise STV-HP1

Page 1: ...Original Instructions Installation Operation Maintenance Manual Saf T Vise STV HP1 and STV HP3 Insertable Tool Holders S CM IOM 00506 3 03 22...

Page 2: ...ability Sentry Equipment Corp its employees agents and the authors and contributors to this document specifically disclaim all liabilities and warranties express or implied including warranties of mer...

Page 3: ...V HP3 Insertable Tool Holder Specifications 6 Installation and Operation 6 Maintenance 7 Inspecting the Safety Cap 7 Prepping the Tool Holder for Reinstallation 7 Cleaning the Rod Probe Shaft 7 Changi...

Page 4: ...ons DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious inj...

Page 5: ...ing with any chemical Read the product label and Material Safety Data Sheets MSDS carefully and follow the instructions exactly Potential Equipment Hazards Hot surfaces This equipment may have very ho...

Page 6: ...wable operating pressure MAP of 5 000 psi at 100 F 344 7 bar at 38 C for the STV HP1 and 7 500 psi at 100 F 517 1 bar at 38 C for the STV HP3 NOTE Flanged units have a MAP based on the class of flange...

Page 7: ...d anti seize lubricant to the holder threads Cleaning the Rod Probe Shaft The rod probe shaft should be cleaned each time the tool holder is removed from the line This helps prevent buildup on the rod...

Page 8: ...arrow at the top of the shaft Use a medium crescent wrench to loosen the adapter lock nut Remove both the adapter and the lock nut Atomizer shaft or quill shaft With a permanent marker mark the rod t...

Page 9: ...For Teflon seal Tighten the upper body until it is snug against the lower body Tighten set screw For graphoil seal Do not tighten the set screw until after installation of the rod shaft Thread but do...

Page 10: ...mount of anti seize lubricant to the shaft end take special care not to get any anti seize lubricant in the shaft as this could clog your nozzle tip b Thread the fluid adapter onto the shaft and tight...

Page 11: ...eaking from the top of the holder body where the rod shaft and body meet the graphoil seal is most likely loose 1 Adjust the top body to tighten the seal a Loosen the small set screw on the upper body...

Page 12: ...ard the top of the holder and then reinstall the locking collet bolt 2 Check the collet for wear A worn collet will not distribute pressure evenly on the rod shaft and may cause damage If the collet i...

Page 13: ...conditioning sampling and measuring gas liquid slurry powder solids steam or water within their production environments our customers obtain the critical insights they need to control and optimize the...

Page 14: ...14 Sentry Equipment Corp This page is intentionally left blank...

Page 15: ...Saf T Vise STV HP1 and STV HP3 15 This page is intentionally left blank...

Page 16: ...sentry equip com 966 Blue Ribbon Circle North Oconomowoc WI 53066 U S A 1 262 567 7256 support sentry equip com Serving customers in more than 50 countries across six continents worldwide...

Reviews: