background image

M6DXF2

P.  / 4

EM-7848 Rev.

2-INPUT MATH FUNCTION MODULE

(PC programmable)

MODEL

M6DXF2

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Signal conditioner ......................................................... (1)

 MODEL NO.

Confirm  Model  No.  marking  on  the  product  to  be  exactly 
what you ordered.

 INSTRUCTION MANUAL

This  manual  describes  necessary  points  of  caution  when 
you use this product, including installation, connection and 
basic maintenance procedures.
The M6DXF2 is programmable using the PC Configurator 
Software.  For detailed information on the PC configuration, 
refer to the M6CFG users manual.  The M6CFG PC Con-
figurator Software is downloadable at M-System’s web site: 
http://www.m-system.co.jp

POINTS OF CAUTION

 CONFORMITY WITH EC DIRECTIVES

• The equipment must be mounted inside a panel.
• The  actual  installation  environments  such  as  panel  con-

figurations, connected devices, connected wires, may affect 
the  protection  level  of  this  unit  when  it  is  integrated  in 
a panel system.  The user may have to review the CE re-
quirements in regard to the whole system and employ ad-
ditional protective measures to ensure the CE conformity.

 POWER INPUT RATING & OPERATIONAL RANGE

Locate the power input rating marked on the product and 
confirm its operational range as indicated below:
  24V DC rating: 24V ±10%, approx. 0.5W

 GENERAL PRECAUTIONS

Before you remove the unit or mount it, turn off the power 
supply and input signal for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -20 to +55°C     

(-4 to +131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 WIRING

• Do  not  install  cables  (power  supply,  input  and  output) 

close  to  noise  sources  (relay  drive  cable,  high  frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

The  unit  is  designed  to  function  as  soon  as  power  is  sup-
plied, however, a warm up for 10 minutes is required for sat-
isfying complete performance described in the data sheet.

COMPONENT IDENTIFICATION

Body

Front Cover

DIN Rail Adaptor

Spec. Marking

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for M-SYSTEM M6D Series

Page 1: ...24 V 10 ripple 10 p p max FUNCTIONS PC Configurator Software is used to change function type Math Functions Temperature compensation w o square root extraction Temperature compensation with square ro...

Page 2: ...ic value within the output range provided that the minimum span is maintained Load resistance Output drive 1 mA max e g 1 5 V 5000 5 V 1 mA If not specified the output range is shown below V2 0 10 V D...

Page 3: ...h setting is required to select input and output types before setting a precise range using PC Configurator Software model M6CFG Refer to the instruction manual for detailed procedures DIMENSIONS unit...

Page 4: ...X0 K1X1 K2X2 A2 where X0 Compensated flow linear characteristics X1 Uncompensated flow X2 Pressure Pressure compensation with square root extraction X0 K1 X1 K2X2 A2 where X0 Compensated flow linear c...

Page 5: ...2 Specifications are subject to change without notice Ruggh lzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox sentronic com www sentronic com Produkte Support und Service S...

Page 6: ...and employ ad ditional protective measures to ensure the CE conformity POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as ind...

Page 7: ...ail A B DIN Rail Adaptor A B C WIRING INSTRUCTIONS Applicable wire size Solid 0 2 to 2 5 mm2 0 55 to 1 75 dia Stranded 0 2 to 2 5 mm2 Tinning wire ends may cause contact failure and therefore is not r...

Page 8: ...ANCE Regular calibration procedure is explained below CALIBRATION Warm up the unit for at least 10 minutes For math functions Apply the input signals which should lead the calculated results as 0 25 5...

Page 9: ...en mounting no extra space is needed between units WIRE INSERTION ANGLE approx 7 SCREWDRIVER INSERTION ANGLE approx 40 EXTERNAL DIMENSIONS unit mm inch Ruggh lzli 2 CH 5453 Busslingen Tel 41 0 56 222...

Reviews: