background image

MODEL: M6DXF2

Euro Terminal Ultra-Slim Signal Conditioners M6D Series

2-INPUT MATH FUNCTION MODULE

(PC programmable)
Functions & Features
• 5.9-mm wide ultra-slim design
• Low profile allows the M6D module mounted in a 120-mm
deep panel
• 2-input math functions and signal selector functions
• PC programmable
• High-density mounting
• Power indicator LED

5.9 (.23)

94

(3.70)

102

(4.02)

mm (inch)

MODEL: M6DXF2-[1][2][3]-R

ORDERING INFORMATION

• Code number:  M6DXF2-[1][2][3]-R
  Specify a code from below for each [1] through [3].
   (e.g. M6DXF2-S2Z1Z1-R)
• Input 1 range (e.g. 1 – 5 V DC)
• Input 2 range (e.g. 4 – 20 mA DC)
• Output range (e.g. 4 – 20 mA DC)

[1] INPUT 1

Current

Z1: Range 0 – 50 mA DC (Input resistance 24.9 Ω)

Voltage

S1: Range -1000 – +1000 mV DC (Input resistance 1 MΩ min.)
S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.)
(Configurator software is used to change the input type and
precise range.)

[2] INPUT 2

Same range availability as Input 1
(Configurator software is used to change the input type and
precise range.)

[3] OUTPUT

Current

Z1: Range 0 – 20 mA DC

Voltage

V2: Range -10 – +10 V DC
V3: Range -5 – +5 V DC
(Configurator software is used to change the output type
and precise range.)

POWER INPUT

DC Power

R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)

FUNCTIONS

PC Configurator Software is used to change function type.
Math Functions:
Temperature compensation (w/o square root extraction)
Temperature compensation (with square root extraction)
Pressure compensation (w/o square root extraction)
Pressure compensation (with square root extraction)
Addition / Subtraction
Multiplication
Division
Signal Selector Functions:
High selector
Low selector

RELATED PRODUCTS

• PC configurator software (model: M6CFG)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC.  Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.

GENERAL SPECIFICATIONS

Connection
Input and output: Euro terminal (torque 0.3 N·m)
Power input: Via the Installation Base (model: M6DBS)
or  Euro terminal (torque 0.3 N·m)
Applicable wire size: 0.2 to 2.5 mm

2

Housing material: Flame-resistant resin (black)
Isolation: Input 1 or input 2 to output to power
No isolation between the inputs. Maintain
the same potential level at both inputs.
Overrange output: -2 – +102 %
(Negative current output is not available.)
Zero adjustment: -2 to +2% (PC programming)
Span adjustment: 98 to 102% (PC programming)

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for M-SYSTEM M6D Series

Page 1: ...24 V 10 ripple 10 p p max FUNCTIONS PC Configurator Software is used to change function type Math Functions Temperature compensation w o square root extraction Temperature compensation with square ro...

Page 2: ...ic value within the output range provided that the minimum span is maintained Load resistance Output drive 1 mA max e g 1 5 V 5000 5 V 1 mA If not specified the output range is shown below V2 0 10 V D...

Page 3: ...h setting is required to select input and output types before setting a precise range using PC Configurator Software model M6CFG Refer to the instruction manual for detailed procedures DIMENSIONS unit...

Page 4: ...X0 K1X1 K2X2 A2 where X0 Compensated flow linear characteristics X1 Uncompensated flow X2 Pressure Pressure compensation with square root extraction X0 K1 X1 K2X2 A2 where X0 Compensated flow linear c...

Page 5: ...2 Specifications are subject to change without notice Ruggh lzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox sentronic com www sentronic com Produkte Support und Service S...

Page 6: ...and employ ad ditional protective measures to ensure the CE conformity POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as ind...

Page 7: ...ail A B DIN Rail Adaptor A B C WIRING INSTRUCTIONS Applicable wire size Solid 0 2 to 2 5 mm2 0 55 to 1 75 dia Stranded 0 2 to 2 5 mm2 Tinning wire ends may cause contact failure and therefore is not r...

Page 8: ...ANCE Regular calibration procedure is explained below CALIBRATION Warm up the unit for at least 10 minutes For math functions Apply the input signals which should lead the calculated results as 0 25 5...

Page 9: ...en mounting no extra space is needed between units WIRE INSERTION ANGLE approx 7 SCREWDRIVER INSERTION ANGLE approx 40 EXTERNAL DIMENSIONS unit mm inch Ruggh lzli 2 CH 5453 Busslingen Tel 41 0 56 222...