MODEL: M2MNV

SWITCHING OPERATIONS

1

2

4

5

7

8

1

2

4

5

7

8

Current Signal (no receiving resistor)

Power : OFF
Switching command : OFF (open)

1

2

4

5

7

8

1

2

4

5

7

8

Power : ON
Switching command : OFF (open)

1

2

4

5

7

8

1

2

4

5

7

8

Power : ON
Switching command : ON (short)

Current Signal (receiving resistor 50

)

Voltage Signal

Current Signal (no receiving resistor)

Transition (ON to OFF, OFF to ON) Status

Power : ON
Switching command : OFF to ON
     or
Power : ON
Switching command : ON to OFF

Current Signal (receiving resistor 50

)

Voltage Signal

*

1. Resistor is provided only for the input code 2: Current signal (receiving resistor 50

).

*

1. Resistor is provided only for the input code 2: Current signal (receiving resistor 50

).

*

1

*

1

*

1

*

1

1

2

4

5

7

8

1

2

4

5

7

8

*

1

*

1

*

1

*

1

• Switching Status

When the switching command contact is switched from 
OFF to ON or from ON to OFF, the signal channel is 
switched only after all photo MOS relays turn on 
(closed).

When the switching command contact is switched from 
OFF to ON or from ON to OFF, the signal channel is 
switched only after all photo MOS relays turn off 
(open).

 INTERLOCKING SWITCHING CONTROL (single-pole contact)

Single contact is used to switch from Signal Channel 1 (A1-B1) to Signal Channel 2 (A2-B1) and vice versa.  

 

CHANNEL 1 (A1)  

 

CHANNEL 2 (A2)

Terminal 3 – 9 OFF (open)   

OFF 

ON

Terminal 3 – 9 ON (closed) 

ON 

OFF

Status LED turn on when the respective channels are alive.  

■ 

INDEPENDENT SWITCHING CONTROL (double-pole contact)

Double contacts are used to independently switch Signal Channel 1 (A1-B1) and Signal Channel 2 (A2-B1).

 

CHANNEL 1 (A1)   

CHANNEL 2 (A2) 

Terminal 3 – 9 OFF (open)   

OFF 

----

Terminal 3 – 9 ON (closed)   

ON 

----

Terminal 6 – 9 OFF (open)   

---- 

OFF

Terminal 6 – 9 ON (closed)   

---- 

ON

Status LED turn on when the respective channels are alive.  

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for M-SYSTEM M2MNV

Page 1: ...Operational voltage range 11 27 V ripple 10 p p max Select N for Standards Approvals code P 110 V DC Operational voltage range 85 150 V ripple 10 p p max 4 OPTIONS multiple selections Standards Approv...

Page 2: ...Switching response time 5 msec Leakage current at open circuit 1 A Line voltage effect 0 1 over voltage range Insulation resistance 100 M with 500 V DC signal channel to switching command contact to p...

Page 3: ...32 11 M3 SCREW 72 2 83 29 5 1 16 2 4 2x5 17x 20 MTG HOLE 6 24 deep When mounting no extra space is needed between units 21 5 85 70 5 2 78 84 3 31 10 39 DIN RAIL 35mm wide 4 16 114 4 49 4 16 Ruggh lzli...

Page 4: ...with the input code 2 Current signal receiving resistor 50 2 Provided only with the input code 1 Current signal no receiving resistor 1 2 Not provided with the input code 3 A1 B1 channel is connected...

Page 5: ...signal channel is switched only after all photo MOS relays turn on closed When the switching command contact is switched from OFF to ON or from ON to OFF the signal channel is switched only after all...

Page 6: ...V Specifications are subject to change without notice Ruggh lzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox sentronic com www sentronic com Produkte Support und Service S...

Page 7: ...e as indicated below 85 264V AC rating 85 264V 47 66 Hz approx 3 5VA 100 240V AC rating 85 264V 47 66 Hz approx 3 5VA 24V DC rating 24V 10 approx 2W 11 27V DC rating 11 27V approx 2W 110V DC rating 85...

Page 8: ...the upper hook at the rear side of base socket on the DIN rail and push in the lower When removing the socket push down the DIN rail adaptor utilizing a minus screwdriver and pull WALL MOUNTING Refer...

Page 9: ...1 2 4 5 7 8 Power ON Switching command ON short Current Signal receiving resistor 50 Voltage Signal Current Signal no receiving resistor Transition ON to OFF OFF to ON Status Power ON Switching comma...

Page 10: ...A2 1 A2 2 3 6 9 SWITCHING COMMAND SW1 INTERLOCKING SWITCHING CONTROL single pole contact U V POWER 10 11 1 7 8 2 4 5 B1 1 B1 2 A1 1 A1 2 A2 1 A2 2 3 6 9 SWITCHING COMMAND SW1 INDEPENDENT SWITCHING CON...

Reviews: