14
Zone or Auxiliary type report:
NN TY MO-DD HR:MM ----line 1
(zone/aux. numbers) ----line 2
Emergency or Station report:
NN TY MO-DD HR:MM ----line 1
STATION ## ----line 2
Opening or Closing report:
NN TY MO-DD HR:MM ----line 1
USER ## ----line 2
Where,
NN
--Event number
DD
--Day of occurrence
TY
--2 character event type (listed below)
HR
--Hour of occurrence (24 hour based)
MO
--Month of occurrence
MM
--Minute of occurrence
The 2 character event type (TY) are listed as follows:
AL
--Zone(s) in alarm
AR
--Alarm memory reset by user
TB
--Zone trouble report
RT
--Zone restore report
BP
--Zone bypass report
AX
--Auxiliary report(s)
E1
--Keypad emergency #1 report
E2
--Keypad emergency #2 report
E3
--Keypad emergency #3 report
E4
--Keypad emergency #4 report
DA
--Door Access ie. "Door Strike"
DU
--Duress report
OP
--Opening report
ST
--Station report
ET
--System Test Mode
CL
--Closing report
#1 - Low battery
#4 - AC restore
#2 - AC fail
#5 - 24 hour test
#3 - Low battery restore
#6 - Up/Down load
#7 - Fail to communicate
TO STEP BACKWARD ONE EVENT:
To view the previous event, simple press the
▲
arrow key.
TO STEP FORWARD ONE EVENT:
To view the next available event, simply press the
▲
arrow key.
TO EXIT THE VIEW HISTORY MODE:
To exit the view history mode, press the
▲
*
key twice. This step
must be done if history viewing is no longer desired since the system
will not automatically exit this mode.
5.2.5
COPY PROM
The Copy Prom feature is used to duplicate a previously
programmed
EEPROM
, the following procedure must be
followed:
1.
Power down the panel.
2.
Install the pre-programmed
EEPROM
into the first
EEPROM
slot marked U10, the new
EEPROM
to be
programmed should be inserted into the second slot
marked U11.
3.
Place the installer “Pass Code Programming” link
P1, on the panel to the upper “Programming” posi-
tion.
4.
Power up the panel again.
5.
Enter the installer menu. NOTE: If the installer
code is unknown, follow the procedures de-
scribed for initializing a new installer code (SEC-
TION 5.4).
6.
Select the “Copy Prom” option from the menu. The
system will start the copying process as soon as the
▲
#
key is pressed. The process will take approxi-
mately 3.5 seconds. The display will show the mes-
sage “Process Passed” if the
EEPROM
is copied and
verified, otherwise the message “Process Failed”,
will be displayed. Enter the installer code again to
clear the message.
7.
Return the P1 link to the "Normal" position.
5.2.6
PROGRAMMING THE KEYPAD ADDRESS
1. Enter the following sequence at the keypad to activate
keypad programming mode:
✚
✚
◆
7
◆
7
◆
7
◆
7
INSTALLER CODE
◆
9
▲
*
0
PRESS SIMULTA NEOUSLY
2.
When you enter programming mode you will be at
location 0. This is indicated by the top line in the
display saying ADDRESS and there will be a colon,
at the left, on the second line of the display. The cursor
will be to the right of the colon.
3.
Using the number keys you can put in the keypad
address value. The keypad address can range from
0 to 3. This is the only location in the SK1L keypad
that needs to be programmed. To change the keypad
address put the cursor on the position next to the
colon and enter a new value. After entering the value
you want press the
▲
#
to save the new value.
4.
To exit keypad programming enter the following se-
quence:
▲
#
▲
*
PRESS SIMULTA NEOUSLY
5.
The panel is now in normal mode and will operate as
a control panel. You must use the correct keypad
number when in partitioned mode to assign the
keypad to the partition you intend.