EN
Instructions for use for the user
p. 23/26
7.7. Changing the maximum heating time
To change the maximum heating time in the Heating Time menu,
press the Minus button
5
and Plus button
6
for 2 seconds.
6H............maximum Time 6 hours
12H............maximum Time 12 hours
24H............maximum Time 24 hours
Use the Minus button
5
or Plus button
6
to select the maximum heating
time. Press the Mode button
7
to confirm the entry.
7.8. Controlling the potential-free switching outputs
To switch the two potential-free switching outputs Opt1. and Opt2. on or off, the
hold down the Minus button
5
or Plus button
6
for 2 seconds. The display
then shows the status of relay 1 or relay 2:
ON.............relay closed
OFF............relay open
NOTE
The controller has two potential-free switching outputs which can are avail-
able for various uses (e.g. opening and closing a motorised ventilation flap).
EN 60335-2-53 specifies a maximum heating time limit of 6 hours for
private infrared cabins. For infrared cabins in hotels, apartment blocks
and similar locations, a maximum heating time limit of 12 hours is
permissible. Extending the heating time limit to 18 hours or 24 hours
is only permitted in public infrared cabins.
!