![Sentiotec just sauna combi series Instructions For Installation And Use Manual Download Page 67](http://html1.mh-extra.com/html/sentiotec/just-sauna-combi-series/just-sauna-combi-series_instructions-for-installation-and-use-manual_1244683067.webp)
WORLD OF WELLNESS
EN
Installation instructions, only for experts
p. 21/46
5.3. Connecting the light
1. Guide the light cable through the cable bushing
c
into the connection area
for 230 V/400 V
g
.
2. Connect the light cable to the terminal strip
e
in accordance with the connec-
tion diagram. Observe the operating instructions for the respective device.
5.4. Connecting the fan (optional)
1. Guide the fan cable through the cable bushing
c
into the connection area
for 230 V/400 V
g
.
2. Connect the fan cable to the terminal strip
e
in accordance with the connec-
tion diagram. Observe the operating instructions for the respective device.
5.5. Connecting the additional output (optional)
The additional output can, for example, be used for an infrared lamp or infrared
heat plates.
WARNING!
Risk of fi re
The additional output does not feature an excess temperature fuse.
For this reason, only intrinsically safe devices should be operated using
the additional output.
●
If infrared lamps are connected to the additional output, these must
have an excess temperature fuse.
●
If infrared heat plates are connected to an additional output, the foil
sensor P-ISX-FF must be used, and must be activated when fi rst
starting operation (see
8.5. Activating/deactivating the foil sen-
sor
on page
28
):
1. Guide the connection cable for the additional device through the cable bush-
ing
8
into the connection area for 230 V/400 V
g
.
2. Connect the power supply cables to the terminal strip
d
in accordance with
the connection diagram. Observe the operating instructions and safety in-
structions for the respective device.