Installation instructions, for professionals only
p. 10/34
WARNING!
Danger of electric shock
Ɣ
The sauna heater may only be installed and connected when the power
supply is disconnected.
4. Installation and connection
Take the following points into account when positioning and connecting the sauna
heater:
Ɣ 7KHHOHFWULFDOFRQQHFWLRQPD\RQO\EHSHUIRUPHGE\DTXDOL¿HGHOHFWULFLDQRU
VLPLODUO\TXDOL¿HGSHUVRQ
Ɣ
A fully disconnecting all-pole isolating device compliant with overvoltage
FDWHJRU\,,,PXVWEH¿WWHGRQVLWH
Ɣ
The Concept R mini combi sauna heater can be used as a wall-mounted
heater or as a free-standing heater. When mounted to the wall, check that
WKHKHDWHUKDVEHHQ¿UPO\LQVWDOOHGRQWKHPRXQWLQJUDLOEHIRUHVWDUWLQJKHDWHU
RSHUDWLRQ:KHQLQVWDOOLQJWKHGHYLFHZLWKIRRWFKHFNWKDWWKHIRRWLQJLV¿UP
4.1. Installation location and sensor position
Position the heater centrally in front of the air intake opening on the cabin wall.
&RPSO\ZLWKWKHVDIHW\LQWHUYDOVWRWKHFDELQZDOOVSHFL¿HGLQ
Fig. 1
.
Install the temperature sensor with overheat cut-out to the cabin wall above the
centre of the sauna heater. Maintain a distance of 15 cm to the sauna cabin roof.