© Copyright Sentient ®. All documentation rights reserved.
19
Figure 2.11 alarm output
[Schedule]:
When the
○
button is highlighted the alarm output function is
only active within the specified/configured time frames during the week.
[Manual]:
When the button is highlighted the alarm output feature will always
be active.
[Stop]:
regardless of what state the system is setup the alarm output feature
will not function when these buttons are selected.
2.5.6 PTZ control
This interface will allow the user to control a PTZ camera that is connected
directly to the recording device.
The functions within the interface include: PTZ direction control, step, zoom,
focus, iris, and setup operation, patrol between spots, trail patrol, boundary
scan, assistant switch, light switch, level rotation, etc.
Note:
1.
To correctly connect the PTZ camera to the DVR the Decoder A (B) line
needs to connect with the DVR A (B) line.
2.
Click
[Main Menu]: > [System Configuration]: > [PTZ setup]:
to set
the PTZ parameters.
3.
The PTZ functions are decided by the PTZ protocols.