Preparing the Installation
Doc 01-G0665
Rev A
Single Phase
3 Phase
115 VAC
230 VAC
230 VAC
460 VAC
575 VAC
AWG
Maximum wire length in feet for 1/3 HP motor
6 700
3,100
4,750
14,225
35,550
8
450 1,950 3,000 8,975 22,425
10 275 1,225 1,900 5,650 14,075
12 175 775 1,175 3,525 8,825
AWG
Maximum wire length in feet for ½ HP motors
6 475
2,075
2,850
14,225
17,775
8
300 1,300 1,800 8,975 11,225
10 200 825 1,125 5,650 7,050
12 125 525 725 3,525
4,425
AWG
Maximum wire length in feet for ¾ HP motors
6
325 1,250 2,050 7,125 11,850
8
225 800 1,300 4,500 7,475
10 150 500 825 2,825
4,700
12 100 325 525 1,775
2,950
AWG
Maximum wire length in feet for 1 hp motors
6
250 950 1,425 5,700 8,900
8 150 600 900 3,600
5,625
10 100 375 575 2,275
3,525
12 75 250 375
1,425
2,
225
Table 5: Power Wiring Chart
System Features
ACTIVITY LED
Steady indication when
gate is at either open or
close limit.
1 second flash when gate
is off a limit in normal
operation.
2 second flash when
entrapment level one has
occurred.
01-G0665F15
Figure 3
AUDIBLE WARNING DEVICE
If the operator should have a second inherent obstruction in sequence with the first;
i.e. back to back, the sounder will activate for 5 minutes then shut off. Also the
sounder can be programmed to come on 2 seconds prior to gate movement and
stay on during gate movement.