background image

www.sentera.eu

MIW-MDB-M-6-EN-000 - 07 / 09 / 2021

7 - 7

back to the table of contents

TRANSPORT AND STORAGE 

Avoid shocks and extreme conditions. Stock in original packing.

WARRANTY AND RESTRICTIONS

Two years from the delivery date against defects in manufacturing. Any modifications  

or alterations to the product after the date of publication relieve the manufacturer 

of any responsibilities. The manufacturer bears no responsibility for any misprints or 
mistakes in this data.

MAINTENANCE 

In normal conditions these controllers are maintenance-free. If soiled, clean with a 

dry or damp cloth. In case of heavy pollution, clean with a non-aggressive product. 

In these circumstances, the unit should be disconnected from the main supply. Pay 

attention that no fluids enter the unit. Only reconnect the controller to the main 

supply when it is completely dry

.

POWER OVER MODBUS 
DISTRIBUTION BOX

MDB-M-6

Summary of Contents for MDB-M-6

Page 1: ...Mounting and operating instructions MDB M 6 POWER OVER MODBUS DISTRIBUTION BOX ...

Page 2: ...CAUTIONS 3 PRODUCT DESCRIPTION 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING AND CONNECTIONS 4 MOUNTING INSTRUCTIONS IN STEPS 5 VERIFICATION OF INSTALLATION 6 TRANSPORT AND STORAGE 6 WARRANTY AND RESTRICTIONS 6 MAINTENANCE 6 POWER OVER MODBUS DISTRIBUTION BOX MDB M 6 ...

Page 3: ...nvironment is as dry as possible avoid condensation All installations shall comply with local health and safety regulations and local electrical standards and approved codes This product can only be installed by an engineer or a technician who has expert knowledge of the product and safety precautions Avoid contacts with energised electrical parts Always disconnect the power supply before connecti...

Page 4: ...ng ambient conditions temperature range 30 70 C rel humidity 20 90 rH non condensing STANDARDS Low Voltage Directive 2014 35 EU EN 60664 1 2007 Insulation coordination for equipment within low voltage systems Part 1 Principles requirements and tests EMC Directive 2014 30 EU EN 55022 2010 Information technology equipment Radio disturbance characteristics Limits and methods of measurement Amendment ...

Page 5: ...f the connected units have a different Power supply only crimp the data wires pins 3 4 5 6 in the RJ45 connectors See Wiring and Connections MOUNTING INSTRUCTIONS IN STEPS Before you start mounting the unit read carefully Safety and Precautions Choose a smooth surface for installation a wall panel etc Follow these steps 1 Unscrew the front cover of the enclosure to remove it 2 Fix the enclosure on...

Page 6: ...s 1 2 7 and 8 connected to different Power supplies If the connected units have a different Power supply only crimp the data wires pins 3 4 5 6 in the RJ45 connectors See Wiring and Connections VERIFICATION OF INSTALLATION When the green LED on the left of each RJ45 socket is on supply voltage is detected see Fig 4 below Fig 4 Power indication ATTENTION The maximum power supply per channel must no...

Page 7: ...e the manufacturer of any responsibilities The manufacturer bears no responsibility for any misprints or mistakes in this data MAINTENANCE In normal conditions these controllers are maintenance free If soiled clean with a dry or damp cloth In case of heavy pollution clean with a non aggressive product In these circumstances the unit should be disconnected from the main supply Pay attention that no...