Sensus 441-S Installation And Maintenance Instructions Manual Download Page 5

3" Model 441-S

Illustration Part

Number

Description

Number

26

Hex Cap Screw, 1/4"–20 x 1/2" Lg.,

910001

120,000 tensile

27

O-Ring, for Orifices

950818

2-1/8" Inlet Orifice, plated steel

090-20-028-00

2-1/8" Inlet Orifice, stainless steel

090-20-028-50

28

1-3/4" Inlet Orifice, plated steel

090-20-028-02

1-3/4" Inlet Orifice, stainless steel

090-20-028-52

1-1/2" Inlet Orifice, plated steel

090-20-028-03

1-1/2" Inlet Orifice, stainless steel

090-20-028-53

2-1/8" Outlet Orifice, plated steel

090-20-029-00

2-1/8" Outlet Orifice, stainless steel

090-20-029-50

29

1-3/4" Outlet Orifice, plated steel

090-20-029-02

1-3/4" Outlet Orifice, stainless steel

090-20-029-52

1-1/2" Outlet Orifice, plated steel

090-20-029-03

1-1/2" Outlet Orifice, stainless steel

090-20-029-53

Valve Assembly, 2-1/8", brass trim,

090-20-515-30

Buna-N (Black, 50-55 Duro)
Valve Assembly, 2-1/8", stainless
steel trim, Buna-N 

090-20-515-50

(Black, 50-55 Duro)

50

Valve Assembly, 2-1/8", brass trim,

090-20-515-40

Polyurethane (Red, 65-75 Duro)
Valve Assembly, 2-1/8", stainless
steel trim, Polyurethane 

090-20-515-60

(Red 65-75 Duro)
Valve Retainer, standard, stainless

090-20-018-30

50b

steel, 2-1/8"
Valve Retainer, v-port wings, 

090-20-012-51

stainless steel, 2-1/8"
Molded Valve, 2-1/8", Buna-N

090-20-315-00

50d

(Black, 50-55 Duro) all trim
Molded Valve, 2-1/8", Polyurethane

090-20-315-02

(Red, 65-75 Duro) all trim

All Models 441-S

Illustration Part

Number

Description

Number

1a

Tetraseal (or O-Ring) 1-3/4 x 2"

904092

4

Hex Cap Screw, 5/16" – 18 x 3/4"

910028

6

Spring Cage Cover Gasket

090-16-066-30

7

Vent Cap, 1/4" NPT

137-02-505-02

9

Spring Cage Gasket

090-16-066-60

13

Thrust Bearing, 3/8" diameter

930510

stainless steel ball

16

Hex Steel Nut, 5/8" – 18

905993

18

Seal Gasket, 2 used

014-76-179-03

7" Diaphragm

090-78-150-21

10" Diaphragm

090-70-150-20

12" Diaphragm

090-71-150-20

20

14" Diaphragm

090-72-150-20

16" Diaphragm

090-73-150-20

18" Diaphragm

090-74-150-20

20" Diaphragm

090-75-150-20

23

O-Ring, 11/16" I.D. 7/8" O.D.

934013

24

Diaphragm Connecting Stem,

090-16-058-00

stainless steel

41

Hex Steel Nut, 3/8" – 16

920853

42

Hex Cap Screw, 3/8" – 16 x 1-3/8" Lg. 903568

45

Travel Indicator Assembly

5

Installation and Maintenance Instructions

Model 441- Regulator

2" Model 441-S

Illustration Part

Number

Description

Number

26

Hex Cap Screw, 1-4"–20 x 1/2" Lg.,

910001

120,000 tensile

27

O-Ring, for Orifices

904832

1-3/4" Inlet Orifice, plated steel

090-16-028-00

28

1-3/4" Inlet Orifice, stainless steel

090-16-028-50

1-1/2" Inlet Orifice, plated steel

090-16-028-01

1-1/2" Inlet Orifice, stainless steel

090-16-028-51

1-3/4" Outlet Orifice, plated steel

090-16-029-00

29

1-3/4" Outlet Orifice, stainless steel

090-16-029-50

1-1/2" Outlet Orifice, plated steel

090-16-029-01

1-1/2" Outlet Orifice, stainless steel

090-16-029-51

Monitoring

The Model 441-S Regulator makes an excellent monitor. It can act 
as a standby regulator installed in series, which assumes control if
a failure in the operating regulator permits the outlet pressure to
exceed the set-point. It can be located in either the upstream 
or the downstream position.

When a Model 441-S Regulator is used to monitor a regulator with
an identical inner valve (another 441 Regulator), the total maximum
capacity through both regulators can be figured at 70% of the
capacity of one regulator alone. This applies with the monitor
located either up or downstream.

For use with gases not listed above, please contact your Sensus
Metering Systems representative or distributor for recommendations.

0.60

Specific gravity of the gas

Correction Factor =

Type of Gas

Correction Factor

Air (specific gravity 1.0)

0.77

Propane (specific gravity 1.53)

0.63

1350 BTU Propane-Air Mixture
(specific gravity 1.20)

0.71

Nitrogen (specific gravity 0.97)

0.79

Dry CO

2

(specific gravity 1.52)

0.63

For other non corrosive gasses use the following formula:

Summary of Contents for 441-S

Page 1: ...RM 1350 R7 Sensus Metering Systems Installation and Maintenance Instructions Model 441 S Regulator T H E G A S I N D U S T R Y ...

Page 2: ...e larger size The 1 2 union 60 contains a small orifice approximately 1 16 diameter This orifice should not be removed Also make certain this orifice is open and free of foreign material Check all connections for leaks CAUTION Turn gas on very slowly If an outlet stop valve is used it should be opened first Do not overload the diaphragm with a sudden surge of inlet pressure Monitor the outlet pres...

Page 3: ...a few turns 50e or 50i screws into 24 but should be loose by 1 2 to 1 turn 3 If orifice 29 was removed reinstall it 4 Inset lower valve assembly and screw into place by a few turns 50h screws into 50e 5 Turn upper valve assembly so Allen screw 50g is accessible through side inspection opening 6 Make the valve lock up adjustment as follows a Hold upper valve against its seat This can be done by han...

Page 4: ...usted using the correction factors on page 5 4 Installation and Maintenance Instructions Model 441 S Regulator To Change Spring 1 Remove seal cap 1 back off adjusting screw 10 remove housing cover 5 and remove spring 14 2 Insert the new spring Be sure it nests correctly onto part 15 3 Complete as per steps 7 8 and 9 under To Assemble 441 S To Service Diaphragm 1 Remove seal cap 1 back off adjustin...

Page 5: ...150 20 20 14 Diaphragm 090 72 150 20 16 Diaphragm 090 73 150 20 18 Diaphragm 090 74 150 20 20 Diaphragm 090 75 150 20 23 O Ring 11 16 I D 7 8 O D 934013 24 Diaphragm Connecting Stem 090 16 058 00 stainless steel 41 Hex Steel Nut 3 8 16 920853 42 Hex Cap Screw 3 8 16 x 1 3 8 Lg 903568 45 Travel Indicator Assembly 5 Installation and Maintenance Instructions Model 441 Regulator 2 Model 441 S Illustra...

Page 6: ...0a Valve Retaining Nut 5 8 18 905564 2 and 3 Model 441 S continued Illustration Part Number Description Number Valve Retainer standard steel 1 3 4 090 16 018 00 Valve Retainer standard 090 16 018 30 stainless steel 1 3 4 Valve Retainer v port wings 090 16 012 53 stainless steel 1 3 4 50b Valve Retainer standard steel 090 16 018 01 1 1 2 Valve Retainer standard 090 16 018 31 stainless steel 1 1 2 V...

Page 7: ... plated steel 090 22 028 02 2 1 8 Inlet Orifice stainless steel 090 22 028 52 1 3 4 Inlet Orifice plated steel 090 22 028 01 1 3 4 Inlet Orifice stainless steel 090 22 028 51 3 Outlet Orifice plated steel 090 22 029 00 3 Outlet Orifice stainless steel 090 22 029 50 29 2 1 8 Outlet Orifice plated steel 090 22 029 02 2 1 8 Outlet Orifice stainless steel 090 22 029 52 1 3 4 Outlet Orifice plated stee...

Page 8: ...2 1 2 14 1 2 Flanged ANSI 300 10 1 2 12 1 2 14 1 2 Pipe Size D E G M N of 441 S 2 6 24 See 5 7 3 6 24 Table 5 7 4 9 1 2 26 Below 5 8 Sensus Metering Systems 2007 Made in USA 805 Liberty Boulevard DuBois PA 15801 800 375 8875 Fax 814 375 8460 www sensus com Limited Warranty Seller warrants the Goods to be free from defects in materials manufactured by Seller and in Seller s workmanship for a period...

Reviews: