Site design
Page 10
UltraWave Product Guide
Power over Ethernet
Silver Network based UltraWave pairs using Ethernet communications have the option of using
Power over Ethernet. To use this powering option requires a PoE class 3 switch that is located
within 100 m (328 ft.) of the transmitter/receiver, and minimum Category 5 network cable. Power
over Ethernet is supplied to the Network Interface card (NIC) and the power output on the NIC is
connected to the power input on the transmitter/receiver. Each unit receiving PoE requires an
earth ground connection.
unit separation
(Rx/Tx)
detection zone
length
wire gauge
(AWG)
power supply
output voltage
number of
UltraWave pairs
perimeter length
100 m (328 ft.)
90 m (295 ft.)
18 AWG
24 VDC
not recommended
N/A
48 VDC
8
720 m (2362 ft.)
150 m (492 ft.)
144 m (472 ft.)
18 AWG
24 VDC
not recommended
N/A
48 VDC
6
864 m (2834 ft.)
200 m (656 ft.)
200 m (656 ft.)
18 AWG
24 VDC
not recommended
N/A
48 VDC
5
1000 m (3280 ft.)
Table 3 Power supply/power cable loads - 18 AWG (power supply connected to one end of perimeter)
unit separation
(Rx/Tx)
detection zone
length
wire gauge
(AWG)
power supply
output voltage
number of
UltraWave pairs
perimeter length
100 m (328 ft.)
90 m (295 ft.)
16 AWG
24 VDC
4
360 m (1181 ft.)
48 VDC
10
900 m (2952 ft.)
150 m (492 ft.)
144 m (472 ft.)
16 AWG
24 VDC
3
432 m (1417 ft.)
48 VDC
8
1152 m (3779 ft.)
200 m (656 ft.)
200 m (656 ft.)
16 AWG
24 VDC
not recommended
N/A
48 VDC
7
1400 m (4593 ft.)
Table 4 Power supply/power cable loads - 16 AWG (power supply connected to one end of perimeter)
Figure 6 24 VDC power distribution example (high-security closed perimeter)
Note
Senstar recommends using a fully managed PoE switch, to supply
power to the UltraWave transmitter/receiver.
Tx
Tx
Rx
Tx
Tx
Rx
Rx
24
VDC
16 AWG
power cable
5 m
5 m
5 m
5 m
5 m
5 m
5 m
5 m
90 m
90 m
90 m
90 m
Rx