background image

SPECIFICATIONS

Kit Number

6-920-3

Type

Recording Ammeter Kit, Three Phase

3 Amcorders

1 IrDA USB Cable

1 Softlink Software

1 Universal Hot Stick Adapter

1 Soft Carrying Case

Range of Operation

 Voltage

69 

kV

 

Current

1 to 1000 A

Resolution

 

Amps 1.0 to 99.9 A

0.1 A

 

Amps 100 to 1000 A

1 A

Accuracy

 

Amps

±1%, ± 2 Counts

Frequency

 

50 Hz

47 to 53 Hz

 

60 Hz

57 to 63 Hz

Mechanical

 

Weight

1.5 lbs, 0.68kg

 

Sensor Opening

up to 1.3 in, up to 3.3 cm

 

Dimensions

9.8 in x 4.8 in x 3 in (24.77 cm x 12.07 cm x 7.62 cm)

 

Housing

Shock and water resistant molded urethane

 

Operating Temperature

-22 to +140˚ F, -30 to +60˚ C

Lithium battery required for temperatures below -4°F (-20°C).

 

Storage Temperature

-40 to +158˚ F, -40 to +70˚ C

 

Hotstick Mounting

Shotgun or Universal Style Hot Stick (Hot Sticks not included)

 

Battery

9 Volt Alkaline or Lithium

Indoor/Outdoor Use

 

Relative Humidity

90% Non - Condensing

 

Altitude

9800 ft, 3000 meters

Software Requirements

Softlink by SensorLink, included in sales kit

Operating System

Windows 7, 8, or 10

Data Collection Space

64,000 Data points

EEC Standards

Successfully passed international test standards indicated by CE

Page 4

Summary of Contents for 920 FRG

Page 1: ...Operators Manual Recording Ammeter Amcorder SensorLink...

Page 2: ...Adapter Model 7 053 Qty 1 sold in 6 920 1 Kit Qty 1 sold in 6 920 3 Kit Universal Switch Stick Receiver Model 7 054 Qty 1 sold in 6 920 1 Kit Qty 3 sold in 6 920 3 Kit Carrying Case Model 659 Qty 1 s...

Page 3: ...cement and Operation 7 Installing on a Line Installing on a line with a Shotgun Hot Stick 8 Installing on a line with a Universal Switch Stick Hot Stick 9 Warranty 19 Quality Assurance Back Cover Soft...

Page 4: ...3 in 24 77 cm x 12 07 cm x 7 62 cm Housing Shock and water resistant molded urethane Operating Temperature 22 to 140 F 30 to 60 C Lithium battery required for temperatures below 4 F 20 C Storage Temp...

Page 5: ...oltage per minimum approach distances stated in published OSHA regulations and or provided by the utility The cover plate chuck and entire Amcorder are to be considered at the same potential Putting t...

Page 6: ...ning The Recorder should be cleaned by wiping with a silicone hot stick wipe to remove dirt sand and salt that will degrade the urethane housing Sample and Log Intervals Sample and Log Interval The Sa...

Page 7: ...sure the reliability of the battery life The Recorder will stop operating when the battery fails to supply more than five volts All the logged data is safely stored in flash memory When a fresh batter...

Page 8: ...ck Shotgun Adapter Urethane Springs Urethane Carabineer Do not install on angled or vertical overhead lines The clamping mechanism is not designed for these lines and doing so will cause the unit to m...

Page 9: ...rt the adapter into the receiver and then twist until the adapter locks into the receiver Step 4 Place the Amcorder on the conductor Step 5 Pull down on the unit to ensure that the urethane springs ar...

Page 10: ...your network administrator for permission and instructions to complete the install if drivers are not installing automatically Softlink Installation Step 1 Softlink Installer is available at www senso...

Page 11: ...has been discovered Communicating with Recorder Softlink communicates with one Recorder at a time To make sure only one Recorder is communicating stand any other Recorders on their base To communicate...

Page 12: ...scroll bar Battery life depends on this setting see page four Synchronization Selecting the Clear all logged data from the Recorder and synchronize logging to the hour box will allow the Recorder to...

Page 13: ...nload the data from any additional units Each unit s data will load into a new tab NOTE Once a fresh battery is inserted the user has 5 minutes to start downloading the data before the Amcorder resets...

Page 14: ...uture review in Softlink or another data management program The data from each recorder is saved into its own file Step 1 Select the data file by selecting the Recorder on the menu Step 2 Select save...

Page 15: ...opening saved files Step 1 Open Softlink Step 2 Close the Discovering ports and instruments bar Step 2 Select Open File Step 3 Find and select the csv or xlsx Softlink file Opening data files in other...

Page 16: ...line thickness The thickness of the graph lines can be changed by the user Thickness is numbered 1 10 and defaults at three The software will show a preview to the user as the value is changed Chart...

Page 17: ...ed measurement parameters will display on the graph Hide and Show Report Options Click the left arrow to hide Report Options Click the right arrow to show the hidden Report options Zoom Window The bot...

Page 18: ...ay not work The IrDA you received with your kit has been tested to work with the Recorders 5 The Serial Number of the IrDA must start with a TA if running Softlink on WIN 10 6 Try restarting Softlink...

Page 19: ...f the instrument 2 Subjected to misuse negligence or accident or 3 Connected installed adjusted or used otherwise than in accordance with the instructions furnished by SensorLink Corporation This Warr...

Page 20: ...___________ I hereby certify that the Model 920 Amcorder has passed all tests defined in the SensorLink Corporation standard I also certify that I have reviewed the standard and test procedure and tha...