5/5
During an adjustment session, all parameters may be reset to their factory values as following:
PARAMETERS OPERATIONS
DEFAULT
VALUES
9
Press the SETUP key (19), then press the NUMBER key 9. All the parameters are reset to the factory values (see next table).
DEFAULT VALUES :
Factory Values Table
Parameter Values
Factory
setting
Sensitivity
1 – 4
3
Hold time
0 – 9
0
Detection field
1 – 9
1
Pulse frequency
1 – 3
2
Output configuration
1 – 2
1
Door control
1 – 3
1
Maximum duration of presence detection
0 – 9
0
The detection pattern is made of 15 independent spots organized in 3 ranges of 5 spots parallel to the door.
Each spot can be individually switched “on” or “off” in order to produce the most adapted detection field. Ex.: a deep and thin field, if
the sensor is facing the seated passengers, or a wide and deep field, if the sensor is covering the platform.
Furthermore, each spot can be set to detect either “motion” (see grey spots below) or “presence” (see black spots below).
Given the many options, a pre-selection of 9 typical sensing fields is programmed into the sensor. These fields can be selected via
the remote control or the push buttons as explained hereafter.
The detection fields are represented with the
optical block tilted at 20°.
Use the Spotfinder to check the position and the
presence of the IR-spots.
SYMPTOMS PROBABLE
CAUSES
CORRECTIVE ACTION
The sensor will not power up.
Faulty power supply.
Assure a correct power supply.
Door keeps opening and closing.
The sensor is disturbed by the door motion
because
1. the detection field is crossed by the door
leaf.
2. of the vibrations caused by the door
movement.
1. Increase the tilt angle of the sensor.
2. Ensure the sensor is fastened correctly.
Two sensors in close proximity are
disturbing each other.
The sensing fields are overlapping.
Choose a different pulse frequency for the sensors (ex.
sensor 1: LOW, sensor 2: MEDIUM)
The sensor does not respond to the
remote control.
1. Batteries in remote control are dead or
installed improperly.
2. Remote control is badly pointed.
3. The sensor is doing a setup.
1. Check to insure that the batteries are installed
correctly, maybe replace batteries.
2. Point the remote control vertically to the sensor.
3. Cut and restore power supply and wait outside of the
detection field until the setup is finished (few seconds)
The sensor does not unlock when the
access code is entered.
Improper code being entered.
Cut and restore power supply. No code is required to
unlock during the first minute after powering. Press on
“unlock”, then on “lock” and introduce a new access
code.
The red LED flashes quickly
(~2 flashes/sec).
Sensor goes into a security mode after an
internal sensor test failed.
Replace sensor.
TROUBLESHOOTING
42.7013 / V1 –
06.08
DETECTION FIELDS
SENSORIO A division of BEA SA - LIEGE Science Park - Allée des Noisetiers 5 - 4031 Angleur [B] - T +32 4 361 65 89 - F +32 4 361 28 58 - [email protected] - www.sensorio.be
DOOR
DOOR
SENSOR
CABLE
Spotfinder