background image

1/5 

 

RS-15

   

USER’S GUIDE

 

 

 

Universal presence and motion sensor for internal doors 

 

 

The RS-15 is a sensor developed to equip automatic inner doors in high-speed trains. The RS-15 has two functions: it detects motion to give an 

opening signal and presence to prevent the door from closing on a stationary person within the presence detection zone. It has been designed to be 

flush mounted. 
 

 

Technology                     

:  Focused active infrared 

with microprocessor 

Optical features 

:  15 independent IR-spots 

producing a square-

shaped detection field 

Mounting height (max) : 

2.5 m 

Tilt angles 

:  0° to 20° (step=5°) 

Detection area  (mounting height=2m; angle=20°) 

 : 

1 m (W) x 1.2 m (D) 

Spot dimension (typical) : 

130 mm (diameter) 

Detection mode 

:  Motion and presence 

Reaction time 

:  < 100ms 

Supply voltage 

:  12V to 30V AC ±10% 

12V to 45V DC ±10% 

Mains frequency 

:  50 to 60 Hz 

Power consumption 

:  < 3W (VA) 

Output relay (free of potential change-over contact) 

 

Max. contact voltage 

:  42V AC - 60V DC 

 

Max. contact current 

:  1A (resistive) 

 

Max. switching power 

:  30W (DC) / 60VA (AC) 

Hold time 

:  0.5s to 10s 

(adjustable)

 

LED : 

Red and green LED 

Connections : 

Integrated 7-pin connector, 

unpluggable 

 

Mounting : 

Designed to be flush-mounted 

Norms and conformity 

:  EMC 2004/108/EEC 

DIN 5510, EN 50155 

Temperature range 

:  -25°C to +55°C 

Degree of protection 

:  IP41 

Dimensions : 

140mm(L) x 38mm(W) x 

55mm(D) 

Weight : 

0.1 kg 

Material : 

ABS 

Color of housing 

:  Black smoked  

Length of cable 

:  1 m (total) 

compliant with DIN5510  

Manual adjustments 

   

 

Sensitivity (by push buttons) 

 

Shape of detection field (by push buttons) 

 

Tilt angle  (mechanically)  

Remote control adjustments 

 

Sensitivity 

 

Hold time 

 

Shape of detection field 

 

 

Max. presence time  

 

Security 

 

4 levels 

From 0.5s to 10s in 10 steps 

Choice of 9 pre-programmed 

fields 

20s to 25min in 10 steps 

4-digit entry code 

 

 
 

 

 

 

Front face 

Bracket 

 

Tilt angle 
adjustment

 

Cable 

 

 
IR-Receiver

 

 

Pin 

 

LED

 

 

Push button A

 

Push button B

 

IR-Emitter

 

 

Wiring 

GREY Relay 

(NC) 

YELLOW Relay 

(NO) 

WHITE Relay 

(COM) 

GREEN Power 

Supply 

BROWN Power 

Supply 

 
After power on, the sensor launches 
a setup for a few seconds. It is 
advisable to stay out of the field to 
finish the setup successfully.

 
 

 

 

 

 

 

Loosen lightly the screws M3 x 8 on both sides in order to slide 
the brackets smoothly. 

Loosen by 2-3 turns the screws M3 x 8 to orient the brackets 
at 90° or 180°. 

2 

Fasten the screws M3 x 8 when the brackets are in the right position. 
Recommended torque: 0.8 Nm; max. torque: 0.9 Nm 

Fasten the brackets to their support by the special pan head screws 

Ø

 3.5 x 9.5. 

 
TECHNICAL 
SPECIFICATIONS

 

 
DESCRIPTION 
AND  
WIRING

 

 
USING THE 
BRACKETS 

Reviews: