background image

 

SEC P/N: 1460014 

 

Rev / ECO: A / 000209 

Page 

5

 of 

26

 

 
 

 

 

I. SPECIFICATIONS 

 

Model: 

SEC3500 HMI

 

 

Interface 

RS485 Port: Interactive “Modbus” (expandable to two) 
RS232 Port: “Statcast” System parameter broadcast 
Ethernet Port: Remote Screen Access 
16 Programmable Relays (expandable to 40) 
 

Construction:

 Powder Coated Steel  

 

Dimensions: 16” X 16” X 10” 
 
Weight: 

45lbs

 

 

Operating Temperature Rating: 

0

 to +50

C at 0 to 99% RH (non-condensing) 

Operating Voltage:  

19 to 29 VDC 

 

   

 

 

Power Consumption:

   40 Watt Max. (Not including relay contact current or 24VDC power 

supplied to external devices) 
 

Relay Contacts

: 1 NO, 1 NC per Relay. 

Contact Rating: 8A @ 30VDC, 8A @ 250VAC 

 

Type AM System 

 

System Components: 

SEC 3500 Operator Interface (Red Lion HMI) 
SEC 3100 Gas Transmitter (Not UL 2017 Approved) 
SEC 3500 - XX Relay Controller 
SEC 3100 AIM Interface Module (Not UL 2017 Approved)

 

SEC 3100 LIM Interface Module (Not UL 2017 Approved)

 

SEC 3100 ISO Repeater  
SEC 3500 Enclosure 
Circuit Breaker 
DC to DC Converter 12-24V to 24V 1A

 

 

Approvals: CSA: C22.2 No 0, No 0.4-04, No 14-05, No 142 
                    UL 508 
ETL: 5002065 UL 2017 (SEC3500 HMI, whole system)  

 

Installation Category:

 Cat. I, Pollution Degree 2 

 

RS485 Max Line Impedance: 

~100-

140Ω 

 

Recommended Power Supply: 

IDEC PS5R-SD24  

Input: 100 to 240VAC Output: 24V 2.5A Power Supply 
Other supplies may be used as long as they are class 2 power supplies 
 

 

Summary of Contents for SEC 3500 HMI

Page 1: ...ECO A 000209 Page 1 of 26 SEC 3500 HMI Operator Interface Hardware Manual Sensor Electronics Corporation 12730 Creek View Avenue Savage Minnesota 55378 USA 952 938 9486 Fax 952 938 9617 Email sales s...

Page 2: ...defective within the warranty would be repaired or replaced at SEC s option SEC will return repaired or replaced equipment pre paid lowest cost freight This warranty does not apply to items which by t...

Page 3: ...SEC P N 1460014 Rev ECO A 000209 Page 3 of 26 Table of Contents Contents I SPECIFICATIONS 5 II GENERAL DESCRIPTION 6 III OPERATION 7 IV INSTALLATION 8 V DRAWINGS 9 VI TESTING 25 VII MAINTENANCE 26...

Page 4: ...cheme Update Specifications Add Installation Steps Add Testing Add Maintenance Add UL2017 Information All 2 10 26 2016 Change model to SEC3500 HMI Add all Components Inside Enclosure to Specs Add Reco...

Page 5: ...ontacts 1 NO 1 NC per Relay Contact Rating 8A 30VDC 8A 250VAC Type AM System System Components SEC 3500 Operator Interface Red Lion HMI SEC 3100 Gas Transmitter Not UL 2017 Approved SEC 3500 XX Relay...

Page 6: ...a power indicator LED located on the front panel of the 3500 Network devices can be interrogated configured and calibrated using the password protected touchscreen user interface 16 embedded programm...

Page 7: ...e SEC3500 HMI Operator Interface is an intuitive operator interface For the individual page operations please refer to the following individual instruction manuals on the SEC website 3500 OI Basic Ope...

Page 8: ...UL 1310 approved Then run the power through the bottom left hole of the SEC 3500 unit Then connect the power supply to the DC to DC converter 3 Run the RS485 Data Highway through the bottom left side...

Page 9: ...SEC P N 1460014 Rev ECO A 000209 Page 9 of 26 Class 2 Power Supply Earth Ground Bolt NOTE COM ON THE SEC 3100 ISO REFERS TO THE ISO COMMON NOT DC COMMON...

Page 10: ...Rev ECO A 000209 Page 10 of 26 V DRAWINGS Part Number Description 1421901 Mounting and Dimensional Drawing 350000016X16X10 Internal Component Layout 1460015 separate document Overall Wiring Diagram W...

Page 11: ...SEC P N 1460014 Rev ECO A 000209 Page 11 of 26...

Page 12: ...SEC P N 1460014 Rev ECO A 000209 Page 12 of 26...

Page 13: ...he SEC 3500 and RS485 Data Highway Connection TB1 Earth Ground Connection 1 2 3 4 5 6 7 8 Ground Stud Enclosure Wall Terminal Description 1 2 AMP Circuit Breaker Power for SEC 3500 only 2 DC Common 3...

Page 14: ...SEC P N 1460014 Rev ECO A 000209 Page 14 of 26 24 VDC POWER SUPPLY 1 2 3 4 5 6 7 8 SEC 3500 Terminal Block WIRING EXAMPLE SEC 3500 TO SEC 3100 TRANSMITTERS AND SEC 3500 8 RELAY CONTROLLER...

Page 15: ...ANALOG OUTPUT TB 3 SENSOR WIRING TB 1 RELAY WIRING BACK VIEW OF SEC 3100 SEC 3100 WIRING SENSOR ELECTRONICS CORPORATION 12730 CREEK VIEW AVE SAVAGE MINNESOTA 55378 USA T 952 938 9486 F 952 938 9617 s...

Page 16: ...ult N O 4 Mid Alarm N C 5 Fault Common 5 Mid Alarm Common 6 Fault N C 6 Mid Alarm N O 1 TB1 6 1 TB2 6 1 TB5 4 1 TB6 6 TB 5 Sensor Wiring TB 6 Power Data Wiring 1 DC Common Black 1 Data A 2 24 VDC Red...

Page 17: ...AMPS 250 VAC OR 8 AMPS 30 VDC COMMUNICATION ISOLATED RS485 MODBUS WEIGHT SEC 3500 8 RELAY CONTROLLER PN 1421999 2 LBS SEC 3500 16 RELAY CONTROLLER PN 1422182 3 LBS POWER SEC 3500 8 RELAY CONTROLLER 4...

Page 18: ...K3 K4 7 8 9 1 01 11 2 1 2 3 4 5 6 K5 K6 K7 K8 7 8 9 1 01 11 2 1 2 3 4 5 6 K9 K10 K11 K12 7 8 9 1 01 11 2 1 2 3 4 5 6 K13 K14 K15 K16 DATA LED POWER LED K1 K2 K3 K4 K5 K6 K7 K8 K16 K15 K14 K13 K12 K11...

Page 19: ...SEC P N 1460014 Rev ECO A 000209 Page 19 of 26 SEC 3500 8 RELAY CONTROLLER DIMENSIONS SEC 3500 16 RELAY CONTROLLER DIMENSIONS...

Page 20: ...junction with the SEC 3100 transmitters and the SEC 3500 HMI Operator Interface or other MODBUS RS 485 data highway systems The SEC 3100 ISO RS 485 Repeater Module is used to extend the distance of th...

Page 21: ...if the SEC 3100 had an SEC gas detector connected The SEC 3100 transmitter reports the foreign device status bidirectional to the SEC 3500 HMI Operator Interface via the MODBUS RS485 communication ne...

Page 22: ...ter Open Path Gas Detector Pyrolyzer Temperature Transmitter Fire Detector SEC 3100 AIM SEC 3100 Transmitter back side NOTE Refer to the SEC 3100 Transmitter Instruction Manual for additional wiring c...

Page 23: ...and High contact closure from the device converts the input signal into a digital signal compatible with the SEC 3100 transmitter The SEC 3100 LIM is factory programmed with the following customer su...

Page 24: ...ransmitter Instruction Manual for additional wiring connections SEC 3100 Explosion Proof Transmitter Switch Device Pressure Switch Open Path Gas Detector Air Flow Switch Temperature Switch Fire Detect...

Page 25: ...ugh these alarms the 3500 screen should show the sensor going into alarm and respond accordingly turn fan on siren lights etc depending on the user s system settings and what the response to those ala...

Page 26: ...ECO A 000209 Page 26 of 26 VII MAINTENANCE Maintenance will need to be done by SEC personal The maintenance needed is minimal If issues arise and maintenance is needed please contact Sensor Electroni...

Reviews: