FT 50 RLA Distance sensor - GB - 068-13799 - 27.07.2010-01
Mounting and
operating instructions
18
7
Operation and Setting
The FT50RLA is ready to operate after applying the operating voltage.
However, the following settings can be made if necessary.
Sensor configuration can be carried out via the control panel using the
S
and
T
keys.
CAUTION
Push buttons only with finger! Do not use sharp objects!
7.1
Displays and configuration elements
Keys and their functions:
General operating functions
Keys Description
In operating mode
In configuration mode
S
T
Entire control
panel
Simultaneous pushing (> 3 s)
activates the setting mode
Push the
T
button first and then also the
S
button.
Then all settings are saved.
After releasing the
S
button, the sensor is in
run mode.
S
SET
No function
Pushing the button briefly changes the respective
function or results in adoption and confirmation of
the set values.
T
Continue
No function
Change settings and select next function.
The LEDs (illustr. 2) indicate the selected settings.
Illustr. 8
06013487
S
T
Q
A
V
N
C
QA
OK
FS
tix
E
fn
oC
BA
ZA
LED Colour Use
Description
BA
Green
Operating indicator
On: ready for operation (Run mode)
Flashing: Set mode is active
ZA
Red
Status indicator
(only active in the Set mode)
Lights: selected setting is active
Q
Yellow
Indicates status of output Q
Lights: switching output active
QA
Yellow
Indicates status of output QA
Lights: object is within the set 0% and
100 % range
Av
Green
Signals operating mode
(speed/averaging)
Lights: operation set with averaging
OK
Green
Stability indicator (good target) Lights: object safely detected and in the
operating range
Nc
Green
Signals switching type N.O./
N.C.for output Q
Lights: switching type N.C. set
FS
Green
Factory Setting
(only active in Set mode)
Lights: factory setting selected