FT 50 RLA Distance sensor - GB - 068-13799 - 27.07.2010-01
17
Mounting and
operating instructions
�
�
�
�
Illustr. 4 Linear movement
15500270
Illustr. 6 Reflective object
15500274
Illustr. 5 Rotating movement
6
Electrical installation
Rotate the connector plug (illustr. 2) so that the
cable
can be connected
easily
,
without kinks
.
Fit socket of the connector cable and screw tight (authorised approx. tightening torque 0.5 to 1 Nm).
Secure connection cable (for example with cable retainer).
Connect sensor according to IIlustr. 7
Illustr. 7
15400176
1
+U
B
BN
3
BU
5
GY
4
BK
2
WH
QA
-U
B
Q
IN
Connection Colour
Use
1 (BN)
Brown
+U
B
= supply voltage
2 (WH)
White
QA = analogue output (4 ... 20 mA)
3 (BU)
Blue
-U
B
= supply voltage
4 (BK)
Black
Q
= switching output
5 (GY)
Grey
IN = control input
when HIGH (+U
B
)
laser-disable*
when LOW (-U
B
)
button lock
when open
free running
* Laser-Disable:
A measurement is only made if the input is connected to -U
B
(buttons are locked) or is open.
The laser is switched off when +U
B
is applied to the input. The switching output and the analogue output retain their
last status.
Once power supply has been connected, the FT 50 RLA is ready for operation after a short stand-by delay
(< 300 ms).
INFORMATION
For maximum precision, please allow for a heating period (approx. 15 minutes).