SENSIRION SFC53 Series Manual Download Page 10

 

www.sensirion.com 

Version 1.0 

 Aug 2022 

 

10 / 11 

Copyright © Sensirion AG 2022.  

 

8.2.

 

Software tools 

8.2.1.

 

Viewer and Recalibration software 

SFC5xxx/SFM5xxx Viewer software 
sensirion.com/media/documents/Sensirion_Mass_Flow_Controllers_SFC5xxx_Viewe.zip

 

 
SFC5xxx/SFM5xxx Viewer Software manual 
sensirion.com/media/documents/GF_AN_SFC5xxx_Viewer_D1.pdf

 

 
SFC5xxx/SFM5xxx Recalibration software 
sensirion.com/media/documents/SFC5xxx_SFM5xxx_RecalibrationTool_V1_72.msi

 

 
SFC5xxx/SFM5xxx Recalibration software manual 

sensirion.com/resource/user_guide/recalibrationtool/sfc5xxx/sfm5xxx 

 

8.2.2.

 

Software drivers 

Python driver 
github.com/Sensirion/python-shdlc-sfc5xxx 
 
LabVIEW, C and C# drivers 
sensirion.com/media/documents/SFC5XXX_Sample_Code.zip

 

 

8.3.

 

Calibration, lifetime and FAQ 

Thanks  to  the  stability  of  the  MEMS-based  sensor  element  and  the  robust  mechanical  design,  Sensirion  Mass  Flow 
Controllers do not drift and do not require recalibration in the field.  
 
High manufacturing standards used during production ensure that our Mass Flow Controllers are extremely reliable and 
have a very low failure rate. This is supported by field surveys and measurements. 
 
Mean time between failures of Sensirion devices has been found to be 169 years. The detailed analysis based on several 
thousand parts in the field can be found in a dedicated application note: 

sensirion.com/resource/application_note/mean_time_between_falilure_analysis 

 
The high-quality valves used are rated for 100 million cycles. The EEPROM memory of the MFC is rated for 50 000 write 
cycles.  This  de-facto  limits  the  number  of  times  a  calibration,  user  gain  etc  can  be  changed.  Please  take  this  into 
consideration, when implementing the Mass Flow Controller. 
 
FAQ: 
sensirion.com/products/support/faq/ 
 
 

 

Summary of Contents for SFC53 Series

Page 1: ...SFM5xxx Summary This guide provides recommendations for evaluation testing and integration of Sensirion Mass Flow Controllers and Meters It is applicable to SFC55xx SFC54xx SFC53xx as well as SFM55xx...

Page 2: ...recommendations 4 4 Common pitfalls 5 4 1 Flow appears to be off by several 5 4 2 Settling time is longer than specified 5 5 Design recommendations 5 5 1 Pressure drop and input pressure 5 6 Fluidic a...

Page 3: ...aluate all digital Mass Flow Controllers with a DB9 plug an adapter is available for other plugs please contact Sensirion EK F5x is available from distribution Please note Mass Flow Controller is not...

Page 4: ...ero flow It is possible to use Sensirion recalibration software to compensate for that effect The Recalibration software can be downloaded from the Sensirion website and is also linked in the Useful r...

Page 5: ...The settling time of Sensirion s Mass Flow Controllers is specified for a step answer from 10 to 100 of full scale within 5 of setpoint When testing the settling time do not do so from a position of z...

Page 6: ...ic manifold must be designed and manufactured by the user In Table 4 in the Useful resources Section 8 1 CAD models for a suggested manifold designs for SFC54xx SFM54xx and SFC53xx SFM53xx can be foun...

Page 7: ...ssure 4 bar at inlet and atmospheric pressure at outlet any situation which leads to the factory calibration requiring adjustments due to the accuracy requirements e g vertical instead of horizontal i...

Page 8: ...ass Flow Controllers SFC sensirion com products product categories mass flow controllers Mass Flow Meters SFM sensirion com products product categories gas flow sensors General technical download sect...

Page 9: ...SFC5500 SFM5500 50sccm 0 5slm 2slm 10slm sensirion com resource cad sfc5500 SFC5400 SFM5400 sensirion com resource datasheet sfc5400 sensirion com resource cad sfc5400 sensirion com media d ocuments...

Page 10: ...to the stability of the MEMS based sensor element and the robust mechanical design Sensirion Mass Flow Controllers do not drift and do not require recalibration in the field High manufacturing standar...

Page 11: ...er s expense and the warranty period for any repaired or replaced product shall be limited to the unexpired portion of the original period This warranty does not apply to any equipment which has not b...

Reviews: