Application features (datalog mode)
This chapter describes the SenlabA application features available in datalog mode
(accessible via SLgateway or SLcodec
–
refer respective User Guide for more details)
Measure data
ID
Description
Type
Unit
Range
current
Measured current of 4-20mA connected
sensor
FLOAT
mA
0...25
battery_current_level
Battery level of the device
UINT8
%
1…100
Event data
ID
Description
Type
Unit
Range
start_event
Happens when device is restarted on the field
BOOL
-
-
Configuration requests
Parameter ID
Description
Type
Unit
Range
Datalog configuration
(ID = request_write_datalog_cfg)
log_period
Device will measure every X minutes
UINT16
Minute
1...1440
(1440=
24h)
log_tx_period
Device will send logged measure every X
minutes (must be a multiple of log_period)
UINT16
Minute
3...1440
log_tx_random_activation
(optional)
Maximize device datalog reliability
BOOL
-
-
Reset battery level
(ID = request_reset_battery_level)
Must be used after battery replacement only
NO PARAMETERS
Stop application
(ID = request_stop_application)
Warning
:
activation with magnet will be
mandatory to reactivate the device
NO PARAMETERS