2011
Sensidyne,
LP
Gilian
GilAir®
Plus
–
Personal
Air
Sampling
Pump
–
Quick
‐
Start
Guide
Page
4
User
Programming
The
GilAir
Plus
has
the
capacity
to
create,
store,
and
execute
up
to
16
user
sampling
program
sequences.
Each
program
can
specify
the
control
mode,
set
point
flow
or
pressure,
and
a
sequence
of
timed
steps
including
time
of
day
to
operate,
on
and
off
periods,
and
a
multi
‐
cycle
capability.
Select
programs
from
the
Run
Mode
menu
item
after
creation
in
the
Run
Setup/Program
menu
item.
Operator
manual
contains
full
documentation.
Maintenance
Battery
GilAir
Plus
employs
a
rechargeable
Nickel
‐
Metal
Hydride
(NiMH)
battery.
Fully
charging
and
properly
maintaining
the
battery
ensures
maximum
run
times.
The
battery
pack
has
a
charge
time
of
less
than
4
hours.
Pump
Filter
Replace
the
internal
pump
filter
when
dirty
or
damaged.
See
the
user
manual
for
instructions.
Specifications
Flow
rate:
20cc/min
to
5000cc/min
in
constant
flow
control;
1cc/min
to
5000
cc/min
in
constant
pressure
control
Operating
Temperature
range:
0
°
C
to
45
°
C
Operating
time
greater
than
8
hours.
All
flow
control
under
ambient
conditions;
STP
model
provides
conversion
of
flow
and
volume
to
Standard
conditions.
Approvals
IECEx
FMG
10.0019X,
Ex
ia
IIC
T4
Ga
Ta
0
°
C
to
45
°
C
ATEX
FM10ATEX0044X;
II
1
G
Ex
ia
IIC
T4
Ga
Ta
0
°
C
to
45
°
C
EN1232
Type
P
Refer
to
the
GilAir
Plus
user
manual
for
full
hazardous
area
classifications
and
approval
information.
Menu
Structure
RUN
FLOW
SET
CALIBRATE
SETUP
►
►
EVENT
ENABLE
(enable
/
disable)
►
PRE/POST
CAL
(enable
/
disable)
►
FAULT
RETRY
(enable
/
disable)
►
VALVE
MODE
(continuous
/
start/stop)
►
AUTOCAL
(Manual
/
Gilibrator
/
TSI
/
Challenger
/
Bios
Defender)
►
CLEAR
DATALOG
►
RUN
OPTIONS
►
►
STANDARD
TEMP
►
STANDARD
PRESSURE
►
DISPLAY
OPTIONS
►
►
LANGUAGE
(English
/
Spanish
/
French
/
Italian
/
Dutch
/
Portuguese
/
German)
►
TEMPERATURE
UNITS
►
PRESSURE
UNITS
(
˝
H
2
O
/
mmHg
/
KPa)
►
CLOCK
SET
►
►
CLOCK
(hours
/
minutes)
►
DATE
(year
/
month
/
date)
►
TIME
FORMAT
(12
hour
/
24
hour)
►
DATE
FORMAT
(mm/dd/yy
/
dd/mm/yy)
►
PASSWORD
(0)
CONTROL
MODE
(CF
/
CPL
/CPH)
RUN
MODE
(Manual
/
Timed
/
PROG
#)
RUN
SETUP
►
►
TIMED
START
(08:00
/
00:00)
►
TIMED
DURATION
(480)
►
PRESS
SET
(
˝
H
2
O)
(18.0)
►
PROGRAM
►
►
ENABLE
(disable
/
enable)
►
PROGRAM
EDIT
►
►
PROG
NAME
(PROG
1)
►
CONTROL
MODE
(CF
/
CPL
/
CPH)
►
SETPOINT
(2000)
►
PROG
STEP
(01)
►
FUNCTION
(Time
/
On
Interval
/
Off
Interval
/
Cycle)
►
FUNCTION
VALUE
00:00
►
SAVE
REVIEW
MAINTENANCE
►
►
FACTORY
DEFAULTS
►
►
GLOBAL
RESET
►
RESET
(SAVE
PROGRAMS)
►
T
‐
AMBIENT
CAL
(Enter
Ta
(
˚
C)
(
Ta
Sensor
(
˚
C)
►
BAROMETRIC
P
CAL
(Enter
PB
(mmHg)
(PB
Sensor
(mmHg)
►
Pressure
(Enter
BP
)