background image

 

 

©

 

2011

 

Sensidyne,

 

LP

 

Gilian

 

GilAir®

 

Plus

 

 

Personal

 

Air

 

Sampling

 

Pump

 

 

Quick

Start

 

Guide

 

Page

 

4

 

User

 

Programming

 

The

 

GilAir

 

Plus

 

has

 

the

 

capacity

 

to

 

create,

 

store,

 

and

 

execute

 

up

 

to

 

16

 

user

 

sampling

 

program

 

sequences.

 

Each

 

program

 

can

 

specify

 

the

 

control

 

mode,

 

set

 

point

 

flow

 

or

 

pressure,

 

and

 

a

 

sequence

 

of

 

timed

 

steps

 

including

 

time

 

of

 

day

 

to

 

operate,

 

on

 

and

 

off

 

periods,

 

and

 

a

 

multi

cycle

 

capability.

 

Select

 

programs

 

from

 

the

 

Run

 

Mode

 

menu

 

item

 

after

 

creation

 

in

 

the

 

Run

 

Setup/Program

 

menu

 

item.

  

Operator

 

manual

 

contains

 

full

 

documentation.

 

 

Maintenance

 

Battery

 

GilAir

 

Plus

 

employs

 

a

 

rechargeable

 

Nickel

Metal

 

Hydride

 

(NiMH)

 

battery.

 

Fully

 

charging

 

and

 

properly

 

maintaining

 

the

 

battery

 

ensures

 

maximum

 

run

 

times.

 

The

 

battery

 

pack

 

has

 

a

 

charge

 

time

 

of

 

less

 

than

 

4

 

hours.

  

 

Pump

 

Filter

 

Replace

 

the

 

internal

 

pump

 

filter

 

when

 

dirty

 

or

 

damaged.

 

See

 

the

 

user

 

manual

 

for

 

instructions.

 

 

Specifications

 

Flow

 

rate:

 

20cc/min

 

to

 

5000cc/min

 

in

 

constant

 

flow

 

control;

 

1cc/min

 

to

 

5000

 

cc/min

 

in

 

constant

 

pressure

 

control

 

Operating

 

Temperature

 

range:

 

0

°

C

 

to

 

45

°

C

   

Operating

  

time

 

greater

 

than

 

8

 

hours.

 

All

 

flow

 

control

 

under

 

ambient

 

conditions;

 

STP

 

model

 

provides

 

conversion

 

of

 

flow

 

and

 

volume

 

to

 

Standard

 

conditions.

 

 

Approvals

 

IECEx

 

FMG

 

10.0019X,

 

Ex

 

ia

 

IIC

 

T4

 

Ga

 

Ta

 

0

°

C

 

to

 

45

°

C

 

ATEX

 

FM10ATEX0044X;

 

II

 

1

 

G

 

Ex

 

ia

 

IIC

 

T4

 

Ga

 

Ta

 

0

°

C

 

to

 

45

°

C

 

EN1232

 

Type

 

P

 

Refer

 

to

 

the

 

GilAir

 

Plus

 

user

 

manual

 

for

 

full

 

hazardous

 

area

 

classifications

 

and

 

approval

 

information.

 

 

Menu

 

Structure

 

RUN

 

FLOW

 

SET

 

CALIBRATE

 

SETUP

 

 

 

EVENT

 

ENABLE

 

(enable

 

/

 

disable)

 

 

PRE/POST

 

CAL

 

(enable

 

/

 

disable)

 

 

FAULT

 

RETRY

 

(enable

 

/

 

disable)

 

 

VALVE

 

MODE

 

(continuous

 

/

 

start/stop)

 

 

AUTOCAL

 

(Manual

 

/

 

Gilibrator

 

/

 

TSI

 

/

 

Challenger

 

/

 

Bios

  

 

 

 

 

 

Defender)

 

 

CLEAR

 

DATALOG

 

 

RUN

 

OPTIONS

 

 

 

 

STANDARD

 

TEMP

 

 

STANDARD

 

PRESSURE

 

 

DISPLAY

 

OPTIONS

 

 

 

LANGUAGE

 

(English

 

/

 

Spanish

 

/

 

French

 

/

 

Italian

 

/

 

Dutch

 

 

 

 

/

 

Portuguese

 

/

 

German)

 

 

TEMPERATURE

 

UNITS

 

 

PRESSURE

 

UNITS

 

(

˝

 

H

2

O

 

/

 

mmHg

 

/

 

KPa)

 

 

CLOCK

 

SET

 

  

 

CLOCK

 

(hours

 

/

 

minutes)

 

 

DATE

 

(year

 

/

 

month

 

/

 

date)

 

 

TIME

 

FORMAT

 

(12

 

hour

 

/

 

24

 

hour)

 

 

DATE

 

FORMAT

 

(mm/dd/yy

 

/

 

dd/mm/yy)

 

 

PASSWORD

 

(0)

 

CONTROL

 

MODE

 

(CF

 

/

 

CPL

 

/CPH)

 

RUN

 

MODE

 

(Manual

 

/

 

Timed

 

/

 

PROG

 

#)

 

RUN

 

SETUP

 

 

 

TIMED

 

START

 

(08:00

 

/

 

00:00)

 

 

TIMED

 

DURATION

 

(480)

 

 

PRESS

 

SET

 

(

˝

 

H

2

O)

 

(18.0)

 

 

PROGRAM

 

 

 

ENABLE

 

(disable

 

/

 

enable)

 

 

PROGRAM

 

EDIT

 

 

 

PROG

 

NAME

            

(PROG

 

1)

 

 

CONTROL

 

MODE

     

(CF

 

/

 

CPL

 

/

 

 

 

 

CPH)

 

 

SETPOINT

 

                

(2000)

 

 

PROG

 

STEP

              

(01)

 

 

FUNCTION

                

(Time

 

/

 

On

 

 

            

Interval

 

/

 

Off

 

Interval

 

/

 

Cycle)

 

 

FUNCTION

 

VALUE

   

00:00

 

 

SAVE

 

 

REVIEW

 

MAINTENANCE

 

 

 

FACTORY

 

DEFAULTS

 

 

 

GLOBAL

 

RESET

 

 

RESET

 

(SAVE

 

PROGRAMS)

 

 

T

AMBIENT

 

CAL

             

(Enter

 

Ta

 

(

˚

C)

 

(

Ta

 

Sensor

 

(

˚

C)

 

 

BAROMETRIC

 

P

 

CAL

     

(Enter

 

PB

 

(mmHg)

 

(PB

 

Sensor

 

(mmHg)

    

Pressure

      

(Enter

 

BP

 

)

    

 