READ AND UNDERSTAND ALL WARNINGS BEFORE USE

Read and understand ALL warnings before using this product. Failure to read, understand, and
comply with ALL warnings could result in property damage, severe personal injury, or death.

Read and understand ALL applicable Federal, State, and Local environmental health and safety
laws and regulations, including OSHA. Ensure complete compliance with ALL applicable laws and
regulations before and during use of this product.

UNDER NO CIRCUMSTANCES should this product be used except by qualified, trained,
technically competent personnel and not until the warnings, 

Operation and Service Manual, labels,

and other literature accompanying this product have been read and understood.

The 

Operation and Service Manual must be read and understood by each user before operating

this product or using its accessories, in order to ensure proper and safe use and installation of this
product and to ensure familiarity with the proper treatment and safety procedures in the event of
an accident.

DO NOT remove, cover, or alter any label or tag on this product, its accessories, or related
products.

DO NOT operate this product should it malfunction or require repair. Operation of a malfunctioning
product, or a product requiring repair may result in serious personal injury or death. DO NOT
attempt to repair or modify the instrument, except as specified in the 

Operation and Service

Manual. Contact the Service Department to arrange for a Returned Material Authorization (RMA).

Use ONLY genuine Sensidyne replacement parts when performing any maintenance procedures
described in this manual. 

Failure to do so may seriously impair instrument performance. Repair or

alteration of the product beyond the scope of these maintenance instructions, or by anyone other
than an authorized service person, could cause the product to fail to perform as designed and
persons who rely on this product for their safety could sustain severe personal injury or death.

DO NOT operate in excessive chemical or water vapor atmospheres. Failure to follow instructions
may cause permanent damage to the equipment.

The BDX

II Abatement Air Sampling Pump employs rechargeable Nickel-Cadmium batteries.

ALWAYS fully charge the battery pack before starting the pump.

DO NOT operate the unit with improperly maintained batteries. This can cause pump failure or
faulting.

DO NOT operate the unit with a dirty or blocked inlet filter. This can cause pump failure or faulting.

DO NOT drop, crush, or roughly handle the unit, and NEVER submerge the unit in water. This can
cause pump failure or faulting.

DO NOT run the pump beyond its recommended specifications.

WARNINGS

Summary of Contents for Gilian BDX-II

Page 1: ...ith specified BDXII Battery Pack Part No 801862 Patent Pending 4 3 2 1 Made in USA by Revision A Document No 801863M 16333 Bay Vista Dr Clearwater FL 33760 800 451 9444 727 539 0550 FAX OPERATION SERV...

Page 2: ...SE WHICH ARE EXPRESSLY DISCLAIMED PROPRIETARY NOTICE This manual was prepared exclusively for the owner of the Gilian BDXII Abatement Air Sam pler The material within this manual is proprietary inform...

Page 3: ...TRODUCTION 1 1 Overview 8 1 2 General Description 8 SECTION TWO OPERATION 2 1 Introduction 11 2 2 Calibration Flow Adjust 11 2 3 Operation 13 SECTION THREE MAINTENANCE 3 1 General Maintenance 14 3 2 B...

Page 4: ...de 20 Appendix D Returned Material Authorization Returned Material Authorization 21 Service Options 21 LIST OF FIGURES 1 1 BDXII Abatement Air Sampler Front View 9 1 2 BDXII Abatement Air Sampler Side...

Page 5: ...eration of a malfunctioning product or a product requiring repair may result in serious personal injury or death DO NOT attempt to repair or modify the instrument except as specified in the Operation...

Page 6: ...hen unit is attached to belt Built in easily readable flowmeter Small long life pump 1 2 GENERAL DESCRIPTION The BDXII Abatement Air Sampler consists of a pump contained in a Lexan plastic case electr...

Page 7: ...1 BDXII Abatement Air Sampler Front view Flow Adj On Off Use only with specified BDXII Battery Pack Part No 801862 Patent Pending 4 3 2 1 INTERNAL EXTERNAL VENT CONTROL OPEN CIRCLE EXTERNAL CLOSED CIR...

Page 8: ...MPLING PUMP 10 Document No 801863M Rev A Figure 1 2 BDXII Abatement Air Sampler Side view INTERNAL EXTERNAL VENT CONTROL RECHARGEABLE BATTERY PACK BATTERY CHARGING JACK BELT CLIP INTERNAL FILTER ASSEM...

Page 9: ...ilter preceding an impinger these sampling media should be installed in line during calibra tion 2 2 CALIBRATION FLOW ADJUST To ensure proper operation of the BDXII Abatement Air Sampling Pump the uni...

Page 10: ...p Calibration Flow Adjust GILIBRATOR 2 or equivalent precision flowmeter FLOW LPM READ INSTRUCTIONS Use only with specified BDXII Battery Pack Part No 801862 CAUTION Patent Pending Made in USA by 4 Fl...

Page 11: ...ery pack preferably overnight to ensure enough power to complete the entire next sampling period The actual time to achieve a fully charged battery pack depends on the charging de vice used see Sectio...

Page 12: ...D for obtaining a Returned Material Authorization 3 2 BATTERY MAINTENANCE The Gilian BDXII Abatement Air Sampler uses rechargeable Nickel Cadmium batter ies The battery packs must be fully charged and...

Page 13: ...Gilian BDXII ABATEMENT AIR SAMPLING PUMP Document No 801863M Rev A 15 Figure 3 1 Battery Pack Removal RECHARGEABLE BATTERY PACK BATTERY CHARGING JACK BATTERY PACK SCREWS 2...

Page 14: ...harge discharge cycles Gilian battery packs are capable of providing 300 500 charging cycles Since this is very difficult to track over the life of the battery Table 3 1 will help you to anticipate ho...

Page 15: ...s on the filter housing Remove the filter hous ing from the unit 4 Remove the filter O ring from the filter housing Remove and discard the old filter CENTER O RING Orange FILTER O RING Black FILTER FI...

Page 16: ...ours Expected Battery Life 300 500 charge recharge cycles Estimated Battery Life 2 5 years 20 hours weekly use 1 5 2 5 years 20 39 hours weekly use 1 1 5 years 40 60 hours weekly use Inactivity for ex...

Page 17: ...r o n r o w s i r o t o m p m u P r i a p e r r o f y r o t c a f o t t i n u n r u t e R k c u t s e b o t s r a e p p a t a o l f r e t e m w o l F s k a e l e v a h y a m m e t s y S r e h t o y f...

Page 18: ...sumes no li ability for service performed by personnel other than Sensidyne personnel To facili tate the repair process please contact the Sensidyne Service Department in advance for assistance with a...

Reviews: