background image

 

 

control4all by SenseNet GmbH 

|

 Guldifeld 42 

|

 3182 Ueberstorf 

|

 031 742 11 21 

|

 

www.control4all.ch 

Mobile to LAN 

If you want to be able to make Inbound Calls (i.e. to a Touch-Panel) apply these Settings 
otherwise leave the Table blank. 

 

Item 

The Rule Number. The Fist matching is taken 

CID 

Caller ID. If you put a “*” any call is accepted. 

URL 

The Format is: 

-

 

<panel_mac_id>@<controller_ip> for a Single Panel 

-

 

<intercom_group>@<controller_ip> for a Intercom Group 

 

 

 

Summary of Contents for control4all

Page 1: ...2014 Roger Althaus control4all 13 06 2014 control4 GSM Gateway Setup ...

Page 2: ...Table of content General 2 Introduction 2 Features 2 Supported Hardware and Software 2 Limitations 2 Installation 3 Installing the Hardware 3 Configuration 4 Prepare control4 System 4 Configure GSM Gateway 5 Logon to Gateway 5 Network Settings 5 Route Settings 6 SIP Settings 8 Troubleshoot 10 ...

Page 3: ...g at the Doorstation with 2 way Audio Trigger the Door Relay to open the Door Ring from a external Phone to a Panel or Intercom Group Sending Text Messages in development Supported Hardware and Software Currently tested and supported control4 Software Version 2 5 3 Koch Door Station control4all Mobile Gateway MV 370 Special Firmware control4 In Wall 7 Touch Screen V2 Limitations tested with Koch D...

Page 4: ...2 11 21 www control4all ch Installation Installing the Hardware Unpack the Device Open the cover on the Backside Locate the SIM Card Slot Place the Card that the Edge of the Card is right in front to you Close the Cover Connect the Antenna Ethernet and Power Supply ...

Page 5: ...storf 031 742 11 21 www control4all ch Configuration Prepare control4 System Launch Composer Connect to Controller Goto System Design Add 3rd Party SIP Phone Driver to Project Enter desired Username and Password i e User 100 and Password 1234 Click Apply ...

Page 6: ...l ch Configure GSM Gateway Logon to Gateway Launch Webbrowser Open http ip_of_gateway and the Logon Window appears default 192 168 0 100 Enter Default Username voip and Password 1234 Click Login Network Settings Verify Network Settings We recommend to use static IP Address Configuration ...

Page 7: ...rol4all by SenseNet GmbH Guldifeld 42 3182 Ueberstorf 031 742 11 21 www control4all ch Route Settings LAN to Mobile Position 0 URL any IP allowed to Dial or i e Subnet 192 168 3 only CallNum Number to dial ...

Page 8: ... to be able to make Inbound Calls i e to a Touch Panel apply these Settings otherwise leave the Table blank Item The Rule Number The Fist matching is taken CID Caller ID If you put a any call is accepted URL The Format is panel_mac_id controller_ip for a Single Panel intercom_group controller_ip for a Intercom Group ...

Page 9: ...ser Name specified in Composer Register Password SIP User Password specified in Composer Domain Server Leave blank Proxy Server Enter IP of control4 controller Outbound Proxy Leave blank Status After rebooting the Gateway check the status is Registered Otherwise check Username Password DTMF Setting These Settings are important if you want to able to trigger the Relay on the Koch Doorstation This c...

Page 10: ...42 3182 Ueberstorf 031 742 11 21 www control4all ch SIP Response Setting Due an incompatibility on the control4 SIP implementation make sure that 183 Session in Progress is set to OFF All other Settings on the Gateway can be left as default ...

Page 11: ...control4all by SenseNet GmbH Guldifeld 42 3182 Ueberstorf 031 742 11 21 www control4all ch Troubleshoot Check Mobile Status Check SIP Settings Status must be registered ...

Reviews: