SENS EnerGenius® DC Wallbox Technical Manual
51
2
0x02 High Battery Temperature
Battery temperature is above the High Battery
Temperature alarm setpoint.
3
0x03
High Battery Temperature
Shutdown
Battery temperature is high enough that the unit has
shut off for safety precautions. Only available when a
remote battery temperature sensor is installed with the
optional remote battery monitor.
4
0x04
High AC Ripple Detected on
Output
Charger's output ripple is above High AC Ripple
Detection alarm setpoint.
5
0x05 DC Output Open
Charger has detected that the output is not connected
to anything.
6
0x06 Charger Low Temperature
Unit ambient temperature is below its rated ambient
temperature, unit output may be derated.
7
0x07 Battery Low Temperature
Battery temperature is below Battery Low Temperature
alarm setpoint. Only available when a remote battery
temperature sensor is installed with the optional remote
battery monitor.
11.7.
Charging AC Alarms Bit Definition
Bit Address
Name
Description
Decimal
Hex
0
0x00 Unused
Unused
1
0x01 AC Phase Missing
An AC phase is missing or out of range. Only available in
a 3-phase capable device.
2
0x02 AC Voltage Over Maximum
AC Voltage has gone above max AC voltage allowed by
the charger on any phase. NOTE: This alarm has a delay
of 3 seconds. Output has been disabled.
3
0x03 AC Voltage Low
AC Voltage has gone below AC Min Voltage alarm
setpoint.
4
0x04 AC Frequency Out Of Range
AC Frequency is outside of the AC High Frequency and
AC Low Frequency alarm setpoints.
5
0x05 AC Voltage High
AC Voltage is above the AC Max Voltage alarm setpoint.
11.8.
Accessory Channel Alarms Bit Definition
Bit Address
Name
Description
Decimal
Hex
0
0x00 Invalid Settings
Setting for this channel are invalid and must be
corrected before settings may be sent to the chargers on
this channel.
1
0x01 Low Current Channel
Channel Current is below Low Current alarm setpoint.
2
0x02 Invalid System Config
System configuration settings are invalid.
11.9.
Accessory System Alarms Bit Definition
Bit Address
Name
Description
Decimal
Hex
0
0x00
Invalid System
Config
Configuration of system is conflicted. Charger will continue to operate
but may not be fully functional until the issue is resolved.
1
0x01
AC1 SPD
The AC supplementary surge protector has expired and needs
replacement.