background image

L 1039-10

  

|

  

9

Cleaning and maintaining the L 1039-10

Indications of the status LEDs

Charging times

With a completely discharged accupack and at room temperature, the charging
times are as follows:

However, charging may take longer under the following circumstances:

• The accupack is deep-discharged and first has to be reconditioned by a deep

discharge recovery charge.

• The ambient temperature is close to or over 45°C/113°F; in order to protect the

accupack, the charging power will be reduced until the accupack temperature
has dropped to an admissible value.

Charging will be aborted and the status LED

will start flashing red under the

following circumstances:

• The accupack temperature is too low or too high (see “Specifications” on

page 11); charging starts automatically when the accupack temperature is
within the charging temperature range.

• The accupack is defective.

Cleaning and maintaining the L 1039-10

Remove all bodypack receivers/transmitters from the charging compartments.

Before cleaning, disconnect the mains unit from the mains. 

Use a soft, dry cloth for cleaning. 

Use a brush or similar to remove dust from the charging compartments.

3

8

2

Status LED 

3

Meaning

lights up red

receiver is being charged

flashes red

error, charging compartment is deactivated (see page 10)

Status LED 

8

Meaning

lights up green

receiver is fully charged

Capacity obtained

Charging time

approx. 100%

typ. 3-4 hours

CAUTION

Liquids can damage the electronics of the product!

Liquids entering the housing of the product can cause a short-circuit and damage
the electronics.

Keep all liquids away from the product. 

Do not use any solvents or cleansing agents.

Summary of Contents for L 1039-10

Page 1: ...L 1039 10 Charger Instruction manual...

Page 2: ...overview 4 Putting the charger into operation 5 Installing the charger 5 Connecting the charger to and disconnecting it from the mains 7 Charging the receivers 8 Indications of the status LEDs 9 Char...

Page 3: ...r long periods of time Only operate the mains unit from the type of power source specified in the chapter Specifications see page 11 Ensure that the mains unit is in a safe operating condition and eas...

Page 4: ...The use of RF transmission allows freedom of movement for all members of the group Due to the possibility of combining the EK 1039 receiver with different transmitters the system can be optimally adap...

Page 5: ...to 10 EK 1039 receivers with the BA 2015 accupacks installed 3 Status LED CHARGE ERROR red 4 Mounting holes e g for mounting the charger into a 19 rack 5 Cable grip for mains cable 6 Hollow jack socke...

Page 6: ...mit specified in the specifications see page 11 Keep the charger away from heat sources and never expose it to direct sunlight CAUTION Risks when rack mounting the charger When installing the product...

Page 7: ...10 You can install the charger fixedly e g in a cabinet or transport case For the dimensions required for fixed installation please refer to the below installation drawing 57 0 mm 132 5 mm 482 mm 465...

Page 8: ...nit to the hollow jack socket 6 of the charger Pass the cable of the mains unit through the cable grip 5 as shown Connect the mains cable EU UK or US version to the mains unit and to a wall socket All...

Page 9: ...stored in the charger s charging compartments or not To make sure that you always use fully charged accupacks we recommend the following steps Fully charge the accupacks for about 4 5 hours before us...

Page 10: ...fications on page 11 charging starts automatically when the accupack temperature is within the charging temperature range The accupack is defective Cleaning and maintaining the L 1039 10 Remove all bo...

Page 11: ...receiver or contacts of the charging compartment are dirty Clean the charging contacts of the receiver and of the charging compartment see page 9 Accupack is defective overaged or defective rechargea...

Page 12: ...95 Dimensions L x H x D without carrying handles approx 482 mm x 70 mm x 132 mm 3 U Weight w o mains unit and accupacks approx 1750 g Europe EMC EN 61000 3 1 EN 61000 3 3 Canada Industry Canada ICES...

Page 13: ...h the following requirements RoHS Directive 2002 95 EC China RoHS ErP Directive 2009 125 EC CE Declaration of Conformity EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC The declaration is a...

Page 14: ...Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Printed in Germany Publ 08 12 549104 A01...

Reviews: