Specification for the Reset Procedure between GuidePort/EMP and Mollie
Simplified hardware diagram:
Remark: Other lines of the GP/Mollie interface are not of interest for this subject.
1. Case: Power is switched on
When the 3.3 V power line becomes high the IC Max811 generates a
≈
280 ms reset
impulse.
2. Case: Reset from Mollie (during power on)
receiver ready
power
285ms
40ms
DSP
reset
IRQA
Reset IC
Max811
Reset for
DSP56303
Master
Reset
GP
Mollie
Reset line
from Mollie
IRQA of DSP
Interrupt_1
3.3 VDC
for digital circuit
10k
Vcc
reset from
Mollie
IRQA
DSP
reset
Tmr
= 5 to 10us
285 ms
40ms
receiver ready