background image

e 908 | 7/8

Specifications

Specifications

Transducer principle

pre-polarised condenser microphone

Frequency response

40 - 20,000 Hz

Pick-up pattern

cardioid

Sensitivity (free field, no load)

4.0 mV/Pa

Nominal impedance (at 1 kHz)

100 Ω (balanced)*

Min. terminating impedance

2 kΩ*

Max. sound pressure level (active)

   e 908 B, e 908 D

   e 908 B ew

35 dB(A)

30 dB(A)

Phantom powering

12 - 48 V*

Connector

   e 908 B, e 908 D

   e 908 B ew

XLR-3*

3.5 mm jack

Dimensions

⌀ 47 x 193 mm

Weight

140 g

* with MZA 900 P (e 908 B/e 908 D); e 908 B ew for direct connection to ew transmitters

Polar pattern

125 Hz

250 Hz

500 Hz

1,000 Hz

2,000 Hz

4,000 Hz
8,000 Hz

16,000 Hz

30°

180°

150°

120°

60°

90°

0
5

10
15
20
25
dB

30°

180°

150°

120°

60°

90°

Frequency response

-40

-50

-60

-70

-80

-90

50

10

0

20

0

50

0

1,0

00

2,0

00

5,0

00

10

,00

0

20

,00

0

Hz

dBV

0°, 1 m

e908_Manual_01_2019_EN.indd   7

26.02.2019   13:58:54

Summary of Contents for EVOLUTION E908

Page 1: ...e 908 Instruction manual e908_Manual_01_2019_EN indd 1 26 02 2019 13 58 51...

Page 2: ...ne clamp MZH 908 B microphone clamp Pouch Pouch Pouch Quick guide Quick guide Quick guide Safety guide Safety guide Safety guide Product overview 2 1 3 5 1 2 3 4 4 e 908 D e 908 B e 908 B ew 1 Microph...

Page 3: ...ting the microphone Plug the 3 5 mm mini jack plug into the 3 5mm jack socket of the MZA 900 P phantom power ad apter included with e 908 B and e 908 D Tighten the coupling ring Plug the XLR cable int...

Page 4: ...e 908 4 8 Installation Using the windshield Place the MZW 908 optional accessories windshield over the microphone head e908_Manual_01_2019_EN indd 4 26 02 2019 13 58 53...

Page 5: ...to one of the two slots Tighten the knurled screw It is vital to observe the following notes Position Resulting sound Commentary D More fundamental Little overtones Position on the drum 3 5 cm above t...

Page 6: ...8 CAUTION LIQUIDS CAN DAMAGE THE ELECTRONICS OF THE PRODUCT Liquids entering the housing of the product can cause a short circuit and damage the electronics Keep all liquids away from the product Do n...

Page 7: ...dB A 30 dB A Phantom powering 12 48 V Connector e 908 B e 908 D e 908 B ew XLR 3 3 5 mm jack Dimensions 47 x 193 mm Weight 140 g with MZA 900 P e 908 B e 908 D e 908 B ew for direct connection to ew...

Page 8: ...e 908 D e 908 B ew 3 5 mm 3 5 mm 3 5 mm Overview of applications Primary application Secondary application e 602 II e 604 e 608 e 609 silver e 614 e 835 e 845 e 865 e 901 e 902 e 904 e 906 e 908 e 91...

Reviews: