background image

14

*) The cardioid pick-up pattern has an opening angle of
approx. 130°. Try to position the microphone so that the
sound source (conference participant, speaker or
instrument) is located in this angle area (see polar
diagram).

Theater stages:
lying at the edge of 
the stage and 
directed towards the 
stage; as spot 
microphone of the PA 
system or for 
monitoring purposes 
in the theater 
cloakrooms

Less room resonance 
in contrast to free-
standing 
microphones;
improved speech 
intelligibility

Excellent rejection 
of rumble noise; if 
necessary, place 
the microphone on 
a soft pad (e.g. 
mousepad).

If necessary, 
combine with 
overhead micro-
phones (e.g. 
Sennheiser ME 36 
with MZH 30 B & 
MZC 30) 

Grand piano / piano:
mounted to the 
inside cover (= 
sound-reflecting 
surface) of the piano
or lying in the 
instrument or on the 
floor underneath the 
piano

Very transparent and 
powerful sound; 
stereo sound image 
can be shaped 
individually, 
depending on 
microphone position 
chosen

Instrument is easy 
to mike, even 
when the cover is 
closed; 
excellent 
protection against 
crosstalk into 
other microphone 
channels and 
reduced volume on 
stage

Summary of Contents for Evolution e 912

Page 1: ...912 Bedienungsanleitung Instuctions for use Notice d emploi Istruzoni per l uso Instruccione para el uso Gebruiksaanwijzing...

Page 2: ...Bedienungsanleitung 3 Instructions for use 11 Notice d emploi 19 Istruzioni per l uso 27 Instrucciones para el uso 35 Gebruiksaanwijzing 43...

Page 3: ...imized for speech vocal and instrument miking The 912 is suitable for use in grand pianos or on theater and opera stages conference tables altars lecterns etc Incidental rear noise is effectively reje...

Page 4: ...e to flat design y Extremely rugged sound inlet basket y Rubber damping plate on base y Mounting slots for mounting the micorphone to e g table tops y Gold plated XLR connector y Integrated electronic...

Page 5: ...ss room resonance portions or comb filter elements improved speech intelligibility and greater gain reserves in contrast to free standing microphones Unobtrusive due to flat design no microphones in t...

Page 6: ...improved speech intelligibility Excellent rejection of rumble noise if necessary place the microphone on a soft pad e g mousepad If necessary combine with overhead micro phones e g Sennheiser ME 36 wi...

Page 7: ...ncy response curve 0 5 10 15 20 25 dB 30 60 90 30 60 90 120 150 180 150 120 2000 Hz 4000 Hz 8000 Hz 16000 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 0 40 50 60 70 20 50 100 200 500 1000 2000 5000 10000 20000 Hz...

Page 8: ...d Sensitivity free field no load at 1 kHz 10 mV Pa Nominal impedance at 1 kHz 100 Min terminating impedance 1 k Phantom powering 48 V 1 1 mA Max sound pressure level at 1 kHz 136 dB SPL Connector XLR...

Page 9: ...tic instruments x x x Orchestra x Trumpet trombone x x x Saxophone x x x Acoustic guitar x Acoustic bass x Guitar amplifiers x Bass amplifiers x Leslie x x x x Piano grand piano x x Kick drums x x Sna...

Page 10: ...manufactured with high quality materials and components which can be recycled and or reused This symbol indicates that electrical and electronic equipment must be disposed of separately from normal wa...

Page 11: ......

Page 12: ...Sennheiser electronic GmbH Co KG 30900 Wedemark Germany Phone 49 5130 600 0 Fax 49 5130 600 300 www sennheiser com Printed in Germany Publ 12 05 511961 A01...