Power packs for the SK 50, SK 250 and SK 3063

B 50-2 and B 250-2 battery pack:

y

3-step LC display for (remaining) battery capacity

y

Reliable Low Batt indication

y

Protection against total discharge

y

Provision of battery status information to the receiver

y

Operating time (with alkaline manganese cells):
B 50-2: > 4.5 hrs on SK 50 / SK 3063
B 250-2: > 9 hrs on SK 50 / SK 3063

> 2.5 hrs on SK 250

BA 50-2 and BA 250-2 accupack:

y

NiMH rechargeable batteries with 1.5 Ah capacity

y

Protection against total discharge

y

Intelligent, 6-step display for (remaining) accupack capacity

y

Charging time max. 2.5 hrs with L 50 charger (depending on
the residual charge of the accupack)

y

Processor-controlled electronics takes self-discharge of
rechargeable battery cells into account

y

Display indicates the maximum possible capacity after the accupack has been fully
charged in the L 50 charger.

y

Measurement of actual capacity and consideration of natural ageing.

y

During operation, the percentage display decreases in correspondence to the
remaining accupack capacity.

y

Note

:  The capacity is calculated during a complete discharge cycle (between full

charge and Low Batt indication). For a correct display of the maximum pos-
sible capacity, discharge the accupack from time to time during normal ope-
ration until the Low Batt indication lights up. The updated capacity is dis-
played after the next complete charge cycle.

y

Operating time:  BA 50-2:

> 6 hrs on SK 50 / SK 3063

BA 250-2: > 10 hrs on SK 50 / SK 3063

> 4.5 h on SK 250

>

<

5

5

Low-Batt

EnergiePack_SK50_SK250_SK3063.fm  Seite 2  Dienstag, 17. Januar 2006  12:17 12