NORMAL OPERATION
PTZ:
Pan, tilt, zoom, focus, and iris commands are converted directly.
Presets: Pelco preset commands from 1~64 are converted directly with a few exceptions.
Pelco Command
Panasonic Command
Autopan
Preset 99 or 29
Autopan ON
Pgm Preset 92 or 22
Set Autopan Start position.
Pgm Preset 93 or 23
Set Autopan End position.
Patrol
Pattern Start
Patrol Learn
Pattern End
Patrol Stop
Pattern Run
Patrol Play
Setup Menu
Pgm Preset 95 or 25
Toggles Camera Menu ON/OFF
(Use pan and tilt commands to navigate the menu.)
Zoom In
Select highlighted menu item
Zoom Out
Return to previous menu
Auxiliary
Aux 5, 6 On
Auto Focus, AutoIris
Aux 7 Off
Autopan cmd = AutoPan
Aux 7 On
Autopan cmd = AutoMode SEQ
Aux 8 On
Autopan cmd = AutoMode SORT
TROUBLESHOOTING
No Video indicator: No video signal detected on the coaxial cable
Only Rx indicator flashes when data is sent, no Error or Tx indicator: wrong address.
Both Rx and Error indicators flash, possible causes:
Controller sending other than Pelco RS-422 camera control data.
Controller sending valid Pelco data but the baudrate parity settings do not match.
Incorrect wiring. Connect controller's Tx+ and Tx- to RS-422 input + and - respectively.
Input Pelco command is not supported to be converted to a Panasonic command.
Error indicator on solidly: Invalid Pelco address selected, must be in the range of 001 ~ 256.
INSTALLATION
Insert the code translator in the video coaxial cable between the camera and the matrix. The video
inputs are a high impedance loop so either can be in or out.
Connect the RS-422 control wires to the code translator's RS-422 in connectors. The baud rate and
parity must be set to match the controller's settings. The code translator will automatically detect
whether it is getting P code or D code. The switches can be changed with power applied and the
changes take effect immediately.
Set address selector switches to the same number the controller is sending for this camera.
July 2017
CONFIGURATION SWITCHES
Switch 1
Unassigned
Switches 2 & 3 Selects baud rate for input Pelco RS-422 data.
Switch 4
Selects parity setting for input Pelco RS-422 data.
Switch 5
Selects Panasonic up the coax protocol.
Down is for all Panasonic cameras that can accept the new "one way" protocol.
Up is for older Panasonic cameras that require "two speed" protocol.
Switch 6
Selects Test Mode. When On, constant square motion (Right, Down, Left, Up)
commands are sent up the coaxial cable as a test.
INDICATORS
The Video indicator will light when there is video present from the camera on the coaxial cable.
The Rx indicator will light when there is any data on the RS-422 input. If it is recognized as valid data
and the received address matches the switch settings, coaxitron data will be sent up the video cable
to the camera and the Tx indicator will flash.The Error indicator will flash if the code translator does not
recognize the input data as valid Pelco data packets.