background image

RE124TG_2GIG-to-GE_Wireless_Translator

 

Page 

1

 of 

24-Hour Tech Support Line: (715)808-0164

 

29-Oct-14

 

www.ResolutionProducts.com

 

 

 

 

 

RE124TG  2GIG

®

-to-GE

®

 Wireless Translator™

 

Features

 

 

Listens to both 2GIG and Honeywell protocol wireless devices. 

 

Also listens to old Honeywell devices from original 2GIG takeover. 

 

Transmits GE protocol wireless. 

 

Enrolls up to 63 devices. 

 

Unique wireless ID for each zone, plus 1 for main device. 

 

All sensor alarm, supervisory and trouble signals are passed through. 

 

Dual antennas for both Receive and Transmit diversity for reliable range. 

 

Back-up battery operation. 

 

Complete supervision of tampers, external power fault and low battery. 

 

Key Instructions

 

 

External supply:  12V DC at least 50 mA.  Power terminals do not care 
which wire is positive or negative! 

 

Mount Translator at least 20 feet from Control Panel’s receiver. 

 

3 AAA Alkaline batteries give 72 hours backup if external supply fails.  

 

INSTALL BATTERIES ONLY WHEN EXTERNAL SUPPLY IS READY TO CONNECT. 

 

Enrolling: 

 

Sensors 

1.

 

Place Panel in Learn Sensors mode. 

2.

 

Press Translator Enroll switch repeatedly until Device Type LED 
matches the type of device you’re enrolling.  ENROLLING AS 
WRONG DEVICE TYPE CAN CAUSE IMPROPER OPERATION. 

3.

 

Activate particular 2GIG (or Honeywell) sensor as follows: 

o

 

PIR:  Tamper – ENROLL PIRs FIRST 
 No tamper on Honeywell 5800PIR-RES: Insert battery 
(Used for PIRs and Glass Break sensors) 

o

 

Panic:  Button 

o

 

Key Fob:  Lower Right 

o

 

DWS:  Tamper 
No tamper on Honeywell DWS: Insert battery 

4.

 

Automatic responses: 

o

 

Green LED blinks on receipt of 2GIG (& HW) packets. 

o

 

Translator beeps on enrollment into Translator. 

o

 

Red LED blinks on transmit of GE packet to panel. 

o

 

The Translator transmits packets to the panel as soon as 
it learns a new sensor.   

5.

 

Panel, if in Learn Sensors mode, will generally learn the GE-
compatible packets simultaneously 

 

Main Translator device  

1.

 

Place Panel in Learn Sensors mode. 

2.

 

Press tamper switch on Translator board.  Enroll in Group 10. 
Translator itself never alarms, but its health needs to be 
monitored like a regular DWS. 

 

Delete all sensors:   

1.

 

Press enroll button repeatedly until all Device Type LEDs are 
off. 

2.

 

Press and hold enroll key for 5 seconds until beep. 

 

Delete just one Device Type:   

1.

 

Press enroll button repeatedly until target Device Type LED is 
lit. 

2.

 

Press and hold enroll key for 5 seconds until beep.

 

RE124TG_2GIG-to-GE_Wireless_Translator

 

Page 

2

 of 

24-Hour Tech Support Line: (715)808-0164

 

29-Oct-14

 

www.ResolutionProducts.com

 

Operation

 

 

 

Existing 2GIG (& Honeywell) protocol sensors transmit as usual.  
Translator passes information on to control panel as if they were GE 
transmitters. 

 
Here is the Fob behavior…

 

2GIG Fob 
Buttons 

HNW Fob 
Buttons 

… do these actions on the GE system

 

Unlock 

OFF 

Unlock 

Away 

ON 

Lock 

Stay 

Left 

Lights 

Away+Disarm  Right 

Double button press: Lock & Unlock 

Star 

 

no action

 

 

 

 

Translator Module Zone wireless transmission ( unique ID): 

Tamper, when cover opened.  Also sends restore. 
Low battery, when low battery.  Also sends restore. 
Supervisory every hour.  Supervisory stopped if 12V DC power absent. 
Translator Module does not send any alarm signals about itself. 

 

 

LED Operation 

 

Green LED 

 

On if 12V DC power present. 

 

Blinks on receipt of Honeywell-compatible packets. 

 

Red LED 

 

On if device low battery (unless there’s no 12V DC 
power). 

 

Blinks on transmit of GE-compatible packets. 

 
 

 

Application Diagram

 

 

New GE 
Wireless 
System 

New GE 
Wireless 
Sensors 

 

Existing 
Honeywell 
Wireless 
Sensors 

Existing 
2GIG 
Wireless 
Sensors 

 