background image

         4

INSTALLATION

REAR PANEL

Power

input

Ernitec

RS-485 input

Connect to the + and - lines

from the Ernitec controller

S = shield (optional)

(Data input is 2400 baud)

Bosch biphase

outputs

The four outputs are identical.

Connect to the Bosch receiver

b and - lines

S = shield (optional)

FRONT PANEL

Power

indicator

The Rx indicator will flash whenever there is data from the Ernitec controller. If the input lines have
reversed polarity, the Rx indicator will be on solidly. Biphase code is repeating, so the Tx indicator
will continue to flash while the camera is moving.

If you have Rx but no Tx, possible causes are:

The Ernitec code coming into the translator is not camera control code.
The Ernitec data out is not set at 2400 baud.

If the code translator is sending data and does not get a follow-up Ernitec command in about 12
seconds, it will time out and quit sending that stream of data.

Ernitec

receive

indicator

Flashes when

receiving RS-485

data

Bosch

transmit

indicator

Flashes continu-
ously while sending
biphase data

BIPHASE DATA OUTPUTS

ERNITEC

RS-485 IN

POWER

12V to 15V

AC or DC

   S

   S

   S

   S

   S

Power

Tx

Rx

CODE TRANSLATOR

Reviews: