4
INSTALLATION
REAR PANEL
Power
input
Ernitec
RS-485 input
Connect to the + and - lines
from the Ernitec controller
S = shield (optional)
(Data input is 2400 baud)
Bosch biphase
outputs
The four outputs are identical.
Connect to the Bosch receiver
b and - lines
S = shield (optional)
FRONT PANEL
Power
indicator
The Rx indicator will flash whenever there is data from the Ernitec controller. If the input lines have
reversed polarity, the Rx indicator will be on solidly. Biphase code is repeating, so the Tx indicator
will continue to flash while the camera is moving.
If you have Rx but no Tx, possible causes are:
The Ernitec code coming into the translator is not camera control code.
The Ernitec data out is not set at 2400 baud.
If the code translator is sending data and does not get a follow-up Ernitec command in about 12
seconds, it will time out and quit sending that stream of data.
Ernitec
receive
indicator
Flashes when
receiving RS-485
data
Bosch
transmit
indicator
Flashes continu-
ously while sending
biphase data
BIPHASE DATA OUTPUTS
ERNITEC
RS-485 IN
POWER
12V to 15V
AC or DC
S
S
S
S
S
Power
Tx
Rx
CODE TRANSLATOR