4
To access the configuration switches, remove the back panel,
which is secured by two screws. Then slide cover back to
expose the switches. The switches can be changed while the
code translator is powered up and the new settings will take
effect immediately.
SW1-5 sets the Vicon baud rate.
SW1-7 & SW1-8 set the Pelco code type and baud rate.
Addressing Notes:
If the code translator is configured to receive "D" code, there
are no addressing options.
For "P" code, the code translator can be configured with an
address input limit of 32 by setting SW1-4 ON. Then the first
three switches can be set so that the output code sent to the
Vicon receivers can be offset to higher numbers.
CONFIGURATION
SWITCH
U11
U10
U9
U8
U13
U6
U3
U4
CN7
CN6
CN5
CN4
CN2
CN1
U2
U1
SW1
SENNETECH
55-9702
SW1-8
"P" CODE BAUD RATE
ON: 9600 BAUD
OFF: 4800 BAUD
(This switch is ignored
if SW1-7 is OFF.)
SW1-7
PELCO CODE TYPE
ON: "P" CODE
OFF: "D" CODE
(Set to match the type of code from
the Pelco control system)
SW1-5
VICON BAUD RATE
ON: 9600 BAUD
OFF: 4800 BAUD
SW1-1, SW1-2, & SW1-3
ADDRESS GROUP SELECTION
for PELCO "P" CODE
SW1
SW2
SW3
GROUP#
OFF
OFF
OFF
GROUP 1
ON
OFF
OFF
GROUP 2
OFF
ON
OFF
GROUP 3
ON
ON
OFF
GROUP 4
OFF
OFF
ON
GROUP 5
ON
OFF
ON
GROUP 6
OFF
ON
ON
GROUP 7
ON
ON
ON
GROUP 8
(These switches are ignored if SW1-4 is OFF
or if SW1-7 is OFF.)
SETTING THE SWITCHES
SW1-4
"P" CODE GROUP SIZE
ON: 32
OFF: 256
(If this switch is OFF,
switches 1~3 are not used.)
SW1-6
MOMENTARY AUX CMD
ON: Momentary
OFF: Latching
(ON simulates pressing and
releasing Vicon Aux key)
1 2 3 4 5 6 7 8
ON
OFF
Summary of Contents for SCT-1024
Page 2: ...2...