background image

4

To access the configuration switches, remove the back panel,
which is secured by two screws. Then slide cover back to
expose the switches. The switches can be changed while the
code translator is powered up and the new settings will take
effect immediately.

SW1-5 sets the Vicon baud rate.
SW1-7 & SW1-8 set the Pelco code type and baud rate.

Addressing Notes:
If the code translator is configured to receive "D" code, there
are no addressing options.

For "P" code, the code translator can be configured with an
address input limit of 32 by setting SW1-4 ON. Then the first
three switches can be set so that the output code sent to the
Vicon receivers can be offset to higher numbers.

CONFIGURATION

SWITCH

U11

U10

U9

U8

U13

U6

U3

U4

CN7

CN6

CN5

CN4

CN2

CN1

U2

U1

SW1

SENNETECH

55-9702

SW1-8

"P" CODE BAUD RATE

ON:   9600 BAUD

OFF: 4800 BAUD

(This switch is ignored

if SW1-7 is OFF.)

SW1-7

PELCO CODE TYPE

ON:   "P" CODE
OFF: "D" CODE

(Set to match the type of code from

the Pelco control system)

SW1-5

VICON BAUD RATE

ON:   9600 BAUD

OFF: 4800 BAUD

SW1-1, SW1-2, & SW1-3

ADDRESS GROUP SELECTION

for PELCO "P" CODE

SW1

SW2

SW3

GROUP#

OFF

OFF

OFF

GROUP 1

ON

OFF

OFF

GROUP 2

OFF

ON

OFF

GROUP 3

ON

ON

OFF

GROUP 4

OFF

OFF

ON

GROUP 5

ON

OFF

ON

GROUP 6

OFF

ON

ON

GROUP 7

ON

ON

ON

GROUP 8

(These switches are ignored if SW1-4 is OFF

or if SW1-7 is OFF.)

SETTING THE SWITCHES

SW1-4

"P" CODE GROUP SIZE

ON: 32

OFF:  256

(If this switch is OFF,

switches 1~3 are not used.)

SW1-6

MOMENTARY AUX CMD

         ON:   Momentary
         OFF: Latching

      (ON simulates pressing and

releasing Vicon Aux key)

1 2 3 4 5 6 7 8

ON

OFF