Secuence of messages: 

 

 
Downlink Message 

It’s possible set the device 

in the cloud without interacting with it locally, defining this type of downlink message 

and CT value on the sigfox backend or in your platform

. That method is optional but it’s not necessary.

 

 

Byte 

2 - 5 

Field 

Easy Meter Setup byte 
(1byte) 

Not used 
(4 bytes) 

Type uplink 
Message 
(1 byte) 

Interval to 
send 
(minutes) 

Not 
Not 
used 

Value 

Bit 7 

1     (by default) 

0x00 0x00 
0x00 0x00 

01 
02 

[10…59]

 

0x00 

Bit 6 

0     (by default) 

Bit 5 

1/0  enable/disable set Type uplink Messsage 

Bit 4 

1/0  enable/disable set Interval to send 

Bit 3 

0     (by default) 

Bit 2 

0     (by default) 

Bit 1 

0     (by default) 

Bit 0 

0     (by default) 

 

Example for downlink message: 
 

B0 00 00 00 00 01 0F 00

   

 With this downlink message set the remote with type of message 01  

and interval to send 15minutes.

 

 
   
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 