background image

MI00138 -E

3

ENGLISH - 4/6

ATTENTION!
BEFORE YOU ATTEMPT USING THE DIP-SWITCH, MAKE SURE 
THAT  YOU  HAVE  DISCONNECTED  ALL  CIRCUITS  AT   
DANGEROUS VOLTAGE.

The  instrument  satisfies  standard  60688/1997;  in  particular,  overvoltage  tests  of  input 
voltage are referred to 

 give in Other Specifications. 

rated input voltage

Voltage  overloads  higher  than  maximum  voltage  given  in  Input  Specifications  may 
damage the instrument.

The range of the instrument is established by the positions of the 4-way DIP-switch. The 
first three ways select one of the 5 preset ranges, while the fourth way (usually off) enables 
the insertion of the trimmer on panel, which gives a continuous-control extended range of 
0..100  Vac  (0..90  Vdc):  if  you  rotate  the  trimmer  clockwise  you  increase  the  output 
(reducing the maximum range of the instrument), else you reduce the output increasing 
the maximum range. If input voltage is present, 

you must use an insulated screwdriver

because the insulation of the adjusting screw is not guaranteed.
Lower  voltage  input  is  4  Vac  o  5  Vdc  for  any  range.  These  values  are  the  amplitude 
thresholds under which the instrument detects 0, that is transmits 4 mA.
 The table below shows the combinations useful for the preset range values.

INPUT FULL SCALE SETTINGS

Range

Range / Trimmer

DIP

100Vac / 90 Vdc

100 Vac + 0..100 Vac / 90 Vdc + 0..90 Vdc

200Vac / 180 Vdc

200 Vac + 0..100 Vac / 180 Vdc + 0..90 Vdc

300Vac / 270 Vdc

300 Vac + 0..100 Vac / 270 Vdc + 0..90 Vdc

400Vac / 360 Vdc

400 Vac + 0..100 Vac / 360 Vdc + 0..90 Vdc

500Vac / 450 Vdc

500 Vac + 0..100 Vac / 450 Vdc + 0..90 Vdc

(1)

DIP

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

on

off

on

off

on

off

on

off

on

off

on

off

on

off

on

off

on

off

on

off

(1): 

Maximum input voltage must not exceed 500 Vac o 710 Vpk anyway.

ATTENTION!
TO  ADJUST  THE  TRIMMER  ON  PANEL  AN  INSULATED 
SCREWDRIVER MUST BE USED.

Summary of Contents for Z202-LP

Page 1: ...anel High precision class 0 3 on 300 Vac of maximum range Wide range of frequency input 20 Hz 400 Hz Extremely short response time 100 ms 3750 Vac galvanic insulation between voltage input and output ports Low output ripple and fast response time to input change ALTERNATE AND DIRECT VOLTAGE TRANSMITTER Z202 LP TECHNICAL SPECIFICATIONS Input Specifications Loop Specifications Voltage input Alternat...

Page 2: ...c 0 3 o m 40 µA 300 Vac 270 Vdc 0 2 o m 30 µA 400 Vac 360 Vdc 0 3 o m 30 µA 500 Vac 450 Vdc 0 3 o m 30 µA Thermal drift 150ppm K EMI Error 40 µA Operating conditions Temperature 20 65 C humidy 30 90 40 C not condensing Climatic Group III Storage Temperature 20 85 C Altitude up to 2000 m a s l International protection IP20 Weight dimensions 140 g 100 x 112 x 17 5 mm Standards EN60688 rated input vo...

Page 3: ...ment vertically in order to arrange the ventilation of the module and pay attention to do not fit any objects or canals that can obstruct its ventilation louvers Avoid fitting modules above equipment that generates heat you are advised to fit them at the bottom of the panel or on the enclosing compartment Overall Dimensions DIP switch Position SWITCH 17 5 mm 100 mm ON KEY ...

Page 4: ...reduce the output increasing the maximum range If input voltage is present you must use an insulated screwdriver because the insulation of the adjusting screw is not guaranteed Lower voltage input is 4 Vac o 5 Vdc for any range These values are the amplitude thresholds under which the instrument detects 0 that is transmits 4 mA The table below shows the combinations useful for the preset range val...

Page 5: ... INSTRUMENT MAKE SURE THAT YOU HAVE DISCONNECTED ALL CIRCUITS AT DANGEROUS VOLTAGE Loop connections RANGE See INPUT FULL SCALE SETTINGS V 12 10 3 1 mA Vext ext supply max 28 V Voltage input connections MI00138 E 3 ENGLISH 5 6 1 3 10 12 Z202 LP ADJ 2 FRONT PANEL TRIMMER ...

Page 6: ...ropean Union and other European countries with separate collection programs This symbol found on your product or on its packaging indicates that this product should not be treated as household waste when you wish to dispose of it Instead it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correc...

Page 7: ......

Page 8: ......

Reviews: