MODULE LAYOUT
Weigh
Case
LED SIGNALS ON THE FRONT PANEL
TECHNICAL SPECIFICATIONS
STANDARDS
EN61000-6-4
electromagnetic emissions, industrial environment
EN61000-6-2
. Electromagnetic immunity, industrial environment
EN61010-1
Safety
INSULATION
ENVIRONMENTAL
CONDITIONS
Temperature:
-20
–
+70°C
Humidity:
30%–90% non-condensing
Storage temperature:
-20
–
+85°C
Protection rating:
IP20
ASSEMBLY
On omega guide DIN IEC EN 60715
CONNECTIONS
Removable 3-way screw terminals, 5 mm pitch for cable up to 2.5
mm
2
, micro USB connector on the front and IDC10 back connector.
POWER SUPPLY
Voltage:
11
–
40 Vdc; 19
–
28 Vac 50
–
60 Hz
Absorption: 2.4
W
111
mm
17.5 mm
102.5 mm
LED
Status
LED meaning
ON
Anomaly on the M-Bus (Meter-Bus)
Device OFF
PWR
ON
OFF
Device ON
TX
Flashing
Transmission of data packet
Flashing
RX
Reception of data packet
120 g.
Materiale PA6, colore nero
1500 Vac
MBUS
ALIMENTAZIONE
RS232
E USB
ENGLISH - 2/4
t