S312A-4-L-4R / S312A-4-H-4R Line

Advanced Analog Indicators
4-Digits Display with 4 relay outputs

Universal  input:  voltage,  current,  thermocouples,,  thermoresistors  (2,  3  or  4  wires 
measurements), potentiometer.
Programmable  retransmission  of  the  measured  instantaneous  value  by  the 

 

isolated

analog output (voltage or active/passive current). 
Filter programmable at 20 levels to stabilise reading.
Temperature measurement displayable in Celsius or Fahrenheit degrees. 
Cold junction compensation in case of thermocouple input.
4 Digits display.
Four  alarms  are  activable  on  the  instantaneous  input  value  (alarm  type:  maximum, 
minimum, automatically resettable or not).  
Alarms status visible through four leds on the frontal panel.
Rs485 serial communication with MODBUS RTU protocol, maximum 32 nodes. 
Four relay outputs for alarms signalling.
Easy navigation on the programming Menu by three buttons on the frontal panel.
Quick configuration of the alarm thresholds by the Quick Alarms Menu. 
Disturbance Rejection at 50 and 60 Hz.
Display contrast settable.
Four relay output: default state for out3 and out4 are settable by internal jumper

1. GENERAL SPECIFICATIONS

2. TECHNICAL SPECIFICATIONS

Potentiometer Input:

Analog Output:

Thermocouple Input:

Thermoresistor Input
(RTD) PT100

Current Input:

Voltage Input:

Power Supply:

Excitation Current: 1,1 mA.
Potentiometer value from 1 k  to 100 k

to use always with a 



parallel resistor equal to 330  .

Generated Current: 0..20 mA, max load resistance: 500  .

Voltage: 0..10 V, min load resistance: 1 k



Configurable Start and Full scale values. 
Resolution: 2  A / 1 mV.

Type: J, K, R, S, T, B, E, N; resolution: 10  V Refer to the 

 

TABLE: TC RANGE

 for the measurement range.

2,  3  or  4  wires  measurement,  excitation  current:  1,1  mA, 
resolution: 0,1 °C. 
Temperature Range : -150 °C..650 °C.
Resistance Range: 20..350  .

0..20 mA, input impedance  20 

Resolution: 10000 points.

0..10 V, input impedance: 100 k

Resolution: 10000 points.

Code S312A-4-L-4R: 10-40 Vdc, 19-28 Vca 50-60 Hz, max 3 W.
Code S312A-4-H-4R: 85-265 Vac 50-60 Hz, max 3 W. 

EN

Summary of Contents for S312A-4-H-4R

Page 1: ...the frontal panel Quick configuration of the alarm thresholds by the QuickAlarms Menu Disturbance Rejection at 50 and 60 Hz Display contrast settable Four relay output default state for out3 and out4...

Page 2: ...erminals pitch 3 5 mm 5 08 mm Three buttons for menu navagation IP65 on the frontal panel with the provided seal 98 2 x 88 5 x 48 mm EN61000 6 4 2002 10 electromagnetic emission industrial environment...

Page 3: ...ggle at the alarm condition and return to the initial status at the end of the alarm condition or at the reset if retained The retained alarms are reset by pressing the buttons for some UP OK MEN seco...

Page 4: ...7 9 10 8 7 THERMOCOUPLE INPUT Resistance R 330 not provided P 1 k 100 k POTENTIOMETER INPUT R 330 P 10 9 8 7 9 10 8 7 The loop is powered by the sensor It is possible to enable the protection of the...

Page 5: ...efault Value Enables the Password for the access to menu Setting a value diffferent from the 5477 password always 5477 will be required at the start of the menu 5477 Password disabled Parameters setta...

Page 6: ...tentiometer It defines also the value of the input signal associated to the maximum value of view Settable Values Values included between the minimum and maximum limits specified for the secleted inpu...

Page 7: ...O N C Relay 2 N O N C 0 N O 0 N O Alarm 1 parameters accessible from menu and identified by the final index 1 Alarm 2 parameters accessible from menu and identified by the final index 2 Alarm 3 parame...

Page 8: ...indication 1 Start scale value indication If the value is set to full scale also the retransmitted output goes to the 100 0 if the value is set to the start scale and the maximum minimum alarms are ac...

Page 9: ...le is blocked while the Modbus communication is available Instantaneous value to display value of the 2 5 or instantaneous value to display minimum displayable Instantaneous value to display value of...

Page 10: ...s revision Register containing the internal code of the firmware Register for the setting of the input type and of the temperature measure unit 40003 40002 40001 R R R W REGISTER MACHINE ID FW_CODE TY...

Page 11: ...minimum threshold 2 Alarm on the maximum threshold 3 Retained alarm on the minimum threshold reset is not automatic 4 Retained alarm on the maximum threshold reset is not automatic Sets the normal sta...

Page 12: ...the minimum threshold 2 Alarm on the maximum threshold 3 Retained alarm on the minimum threshold reset is not automatic 4 Retained alarm on the maximum threshold reset is not automatic Not used Sets t...

Page 13: ...esis R W R W 40014 40015 Bit 15 0 Bit 15 0 Alarm 1 threshold value referred to the view scale but without decimal point For example if the value referred to the view scale is 20 0 sets 200 See HI_T fo...

Page 14: ...t decimal point Example if the value referred to the view scale is 10 0 set 100 Default 1000 Min value 1999 Max value 9999 LO_T Displayed value correspondent to the minimum value of the analog output...

Page 15: ...7 00000000 0x00 4800 00000001 0x01 9600 00000010 0x02 19200 00000011 0x03 38400 Response delay time It represents the number of pauses of 6 characters each to be entered between the end of the Rx mess...

Page 16: ...39 049 8705355 8705359 Fax 39 049 8706287 e mail info seneca it www seneca it THE INTERNATIONAL CERTIFICATION NETWORK R ISO9001 2000 This document is property of SENECAsrl Duplication and reprodution...

Page 17: ...MI002502 E 11 11 1 11 2 11 3...

Page 18: ...MI002502 E 11 7 11 4 11 5 11 6 DEFAULT SETTING SYSTEM...

Page 19: ...MI002502 E...

Page 20: ...MI002502 E...

Page 21: ...reshold Alarm 4 threshold Alarm 4 Type Alarm 3 Hysteresys Alarm 4 Hysteresis Alarm 3 Type Relay 3 N O or N C Relay 4 N O or N C Alarm 3 threshold Alarm 4 threshold Alarm 2 threshold Alarm 1 threshold...

Reviews: