R

etransmission range

Reactive Power

Electrical Quantity

Measurement Range

V rms

0..600 Vac

I rms

Active Power

Apparent Power

Cos

Frequency

0..1000 A

(0..1000 * 600)W

(0..1000 * 600)VAR

(0..1000 * 600)VA

0..1

40..70 Hz

CLOSURE HOOK
AND SYMBOL OF
CURRENT 
DIRECTION

PHASE
CONDUCTOR

ROGOWSKI’s
COIL

Current
direction
in the 
conductor

WIRE (+)

WIRE (-)

SHIELD

(if present)

-  For  an  more  accurate  measurement,  place  the  cable  conductor  in  a  central 
position with reference to the ring
- For a correct measurement, calibrate the Rogowski’s coil: write the calibration 
coefficient to the corresponding Modbus register (refer to the user manual) or set it 
using the menu on the display (see display programming manual).
Example: if the Rogowski’s coil feature is 90 mV / 1000 A, set the tarature register 
(corresponding to the phase where the Rogowski’s coil is applied) with the value: 
1000 / (90 · 10).

NOTE  ABOUT  ACCURACY

:  The  device  is  provided  with  0.5%  accuracy.

Global  accuracy  is  the  sum  between  the  device  accuracy  and  the  connected 
Rogowski’s coil accuracy.

Summary of Contents for S Series

Page 1: ...iguration software please see www seneca it Contents General Specifications Technical Specifications Installation Rules Electrical connections Modbus connection rules DIP switches settings Digital inputs Leds Signallings Factory Settings Contents General specifications Technical features Functioning Rogowski s coil Electrical quantities Electrical connections LEDs signallings Serial interface Case...

Page 2: ...se chosen by specific display or MODBUS registry The module is also distinguished by Communication configurability through software RS485 serial communication with MODBUS RTU protocol maximum 32 nodes Easy wiring of power supply and serial bus by means of the bus housed in the DIN rail High precision 0 5 class Protection against ESD discharge up to 4 kV Measure input insulation 4000 Vac towards al...

Page 3: ...ntal conditions Voltage Consumption 11 40 VDC or 19 28 VAC 50 60 Hz Max 2 5 W Temperature Humidity 10 65 C 30 90 Voltage Output Analog Output 0 10 Vdc 0 5 Vdc Min load resistance 2 k Current Output 0 20 mA 4 20 mA Max load resistance 500 Transmission error Response time 0 1 max range 2 s 10 90 Isolations Insulation voltage 4000 Vac between the input and all the other circuits 1500 Vac between powe...

Page 4: ...A and the quantity to transmit is voltage Vrms in the 10 300 V range therefore MIN 10 MAX 300 then if Vrms measured is 10V analog output will be 4mA while if Vrms 300V output will be 20mA In the intermediate points the behaviour is linear The analog output values saturate at approximately 11 V for voltage output and at 22mA for current output analog output clamped at 110 If network frequency oscil...

Page 5: ...e conductor in a central position with reference to the ring For a correct measurement calibrate the Rogowski s coil write the calibration coefficient to the corresponding Modbus register refer to the user manual or set it using the menu on the display see display programming manual Example if the Rogowski s coil feature is 90 mV 1000 A set the tarature register corresponding to the phase where th...

Page 6: ...9 18 17 16 15 14 13 ZL x x VG A C B 22 21 20 19 18 17 16 15 14 13 N ZL x x x 3 WIRES Three Phase without Neutral VG A C B 22 21 20 19 18 17 16 15 14 13 N ZL x x x VG A C B 22 21 20 19 18 17 16 15 14 13 N ZL x x x There is no insulation between RS485 and the analog output 4 WIRES Three Phase with Neutral Note Connect the shield of the Rogowski s coil at negative so one of the terminals 14 16 18 22 ...

Page 7: ...o the energy counter Imax V R 50 mA Vmax 28V For more informations see the display settings manual For detailed information on RS485 serial interface consult the documentation provided by the website www seneca it in the section Prodotti Serie Z PC MODBUS TUTORIAL SERIAL INTERFACE Digital output 29 30 I R V ANALOG OUTPUT The module provides a programmable analog output in voltage 0 10 Vdc or activ...

Page 8: ...ill help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of this product The recycling of materials will help to conserve natural resources For more detailed information about the recycling of the product please contact your local city office waste disposal service of the retail store where you purchased this pro...

Reviews: