APP INITIALISATION AND OPERATION

1) Toolbar:

play/pause: detection or datalogger.

reset: sampling time,

enable/disable: saves the value and

shows it as relative on the display,

both in analogue and digital format.

Capture screen: saves a screen

shot in the photo gallery, with the

option of exporting or sharing it

settings

2) MIN/AVG/MAX value panel.

Real-time chart of the detected value (*).

Using the

settings button

, it is possible to

read the model and the serial number of the

probe detected.

Below it is possible to configure:

Unit of measure

Datalogger enable/frequency

Measurement scale

Real time measurement log

Alarm  thresholds,  with  and  without

SMS,  with  warning  sound  and/or

vibration,  recipients  from  address

book or direct entry

The panel of the datalogger sessions gives

the possibility of exporting the data in CSV

format  for  processing  on  spreadsheet,  or

for  loading  on  an  analysis  software  like

Easy Log Viewer.

CSV file format:

INDEX:  row  index,  incremental

number.

TYPE: LOG row type.

TIMESTAMP:  date  and  time  of  the

measurement  (time  and  device

language settings).

Summary of Contents for MY-PT

Page 1: ...d devices SENECA MI004330 E pag 1 INSTRUCTION MANUAL MY PT PT100 professional portable temperature probes for Android devices with microUSB OTG port SENECA S r l Via Austria 26 35127 Z I PADOVA PD ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 www seneca it ...

Page 2: ...se if the instructions contained in this manual are not followed Do not expose handles and cables to temperatures exceeding 70 C if they are not specifically approved to withstand such temperatures Electrical and electronic waste disposal applicable in the European Union and other countries with recycling policies The symbol found on the product or package indicates that the product must be handed...

Page 3: ...g steel ring nut Flashing LED Connection and transmission with the Android device Power supply From the Android device through the microUSB OTG port Consumption 25 mA Ambient conditions 20 50 C handle Interface microUSB Precision 0 5 of the measurement 0 4 C probe handpiece assembly Stability of temperature measurement 0 01 K 100 ppm K Measurement range 30 300 C Response time 15 s Storage temperat...

Page 4: ...ike smartphones or tablets into data acquisition systems These probes give the possibility of displaying on your device PT100 temperature values in analogue or digital format and of sharing the data through the most common communication channels like e mail SMS etc These probes guarantee professional certified and industrial measurements both for diagnostic purposes and for monitoring environmenta...

Page 5: ...MY Series Professional portable temperature probes for Android devices SENECA MI004330 E pag 5 CONNECTING THE PROBE TO THE HANDPIECE ...

Page 6: ...ous value detected both in analogue and digital format The centre of the screen shows the function keys while the bottom provides a quick view of the data collected in real time in chart format During operation the PIV App disables automatic screen lock so that the measurements can continue to be displayed for the user The display will only go off when the screen is manually put in stand by mode b...

Page 7: ...Using the settings button it is possible to read the model and the serial number of the probe detected Below it is possible to configure Unit of measure Datalogger enable frequency Measurement scale Real time measurement log Alarm thresholds with and without SMS with warning sound and or vibration recipients from address book or direct entry The panel of the datalogger sessions gives the possibili...

Page 8: ...t as an e mail attachment When the set threshold is exceeded a flashing icon indicates that an alarm is present or that the threshold has been exceeded During this stage if set to do so your device will send a notification SMS to the recipients The device will not send any further SMS until the alarm is rearmed Touch icon 1 to scroll the alarm log The reset key can be used to reset rearm the alarm...

Reviews: