background image

 

09/2019

- 10 -

 Copyright © 2019, Fast ČR, a.s.

EN

Dehumidifier

User's manual

Prior to using this appliance, please read the user's manual thoroughly, even in cases, 

when one has already familiarised themselves with previous use of similar types of 

appliances. Only use the appliance in the manner described in this user’s manual. 

Keep this user's manual in a safe place where it can be easily retrieved for future use. 

We recommend saving the original cardboard box, packaging material, purchase receipt 

and responsibility statement of the vendor or warranty card for at least the duration of 

the legal liability for unsatisfactory performance or quality. In the event of transportation, 

we recommend that you pack the appliance in the original box from the manufacturer.

DESCRIPTION OF THE APPLIANCE

A1 

Control panel

A2 

Front cover

A3 

Condensate tank

A4 

Viewing window

A5 

Handles (on both sides)

A6 

Drain hose outlet connection 

(only for continuous draining of 

condensate)

A7 

Travel wheels

A8 

Power cord holder (used only for 

storage)

A9 

Air filter (located behind a grille)

A10 

Air outlet grille

 

Not shown

 

-  Threaded end

DESCRIPTION OF THE CONTROL PANEL

B1 

COMFORT button (intelligent room 

humidity control mode)

B2 

FILTER button (air filter cleaning 

check)

B3 

CONT. button (for continuous 

draining of condensate)

B4 

TURBO button (fan speed control)

B5 

TIMER button (timer control)

B6 

/

 buttons

B7 

On/Off button

B8 

Display

B9 

Automatic start indicator light

B10 

Automatic shut-off indicator light

B11 

Full condensate tank indicator light

B12 

Automatic defrost indicator light

BEFORE FIRST USE

Before first use, take the appliance and its accessories out of the packaging material 

and remove all promotional labels and stickers. Check that neither the appliance nor 

any of its parts is damaged.

Note: 

Travel wheels 

A7

 may be removed on certain models. Screw the travel wheels 

to the underside of the appliance prior to using it.

Do not travel over carpets, door thresholds or other obstacles with the wheels. 

This could damage them. 

Do not move the appliance when the condensate tank is full.

Certain models may also be supplied without travel wheels 

A7

.

Installing the power cord holder

When planning on not using the appliance and preparing to store it, install the holder 

that serves to conveniently store the power cord.

Insert the holder into the cut-out at the rear of the appliance – see figure C.

INSTALLATION LOCATION OF THE APPLIANCE

Locate the appliance on an even, dry and stable surface within reach of a properly 

grounded power socket.

Do not use the appliance outdoors.

To ensure sufficient air circulation, leave at least 20 cm of free space around the sides 

of the appliance.

Locate the appliance in a room where temperature does not fall below 5 °C. If the 

temperature were to fall below 5 °C, there is a risk of frost forming inside the appliance, 

which would reduce its efficiency.

Do not locate the appliance in the vicinity of dryers, heating devices and other sources 

of heat.

Use the appliance in locations where humidity could damage books or other valuable 

items.

The appliance must be used in a  closed room in order to ensure its maximum 

effectiveness. Therefore, close the doors and windows of the given room.

OPERATING THE APPLIANCE

The dehumidifier is used for drying out, for example, flooded basements, rooms with 

an increased level of moisture, etc. Do not use it in areas where substances or items are 

stored requiring precise room temperature and humidity control.

If using the appliance for the first time, it is important to allow it to run continuously 

for 24 hours.

Use the appliance at an ambient temperature in the range 5 °C – 32 °C (41 °F – 90 °F) 

and humidity in the range 30 % - 80 %.

Always wait at least 3 minutes before turning the appliance on again.

Do not connect the appliance to a power socket to which another appliance is already 

connected. We recommend connecting the appliance to an independent circuit.

Make sure that the condensate tank is correctly installed in the appliance, otherwise the 

appliance may not function correctly.

OPERATING THE APPLIANCE

Make sure that the appliance is located in a suitable place and that it is correctly 

assembled. Then insert the power plug into a power socket.

Turning on / off

Press button 

B7

 to turn on the appliance. In order to turn off the appliance, press 

button 

B7

 again.

The appliance will turn off automatically if the condensate tank 

A3

 is full or incorrectly 

installed.

If you turn the appliance off and then need to turn it on again quickly thereafter, the 

appliance will start again after approximately 3 minutes. This function protects the 

compressor against damage.

The appliance is equipped with an automatic restart function (AUTO-RESTART) for the 

event of a power outage. Settings will remain stored in the memory of the appliance, and 

after power is restored, the appliance will automatically start in the previously set mode.

When you have finished using it, turn off the appliance and disconnect the power cord 

from the power socket.

Display

Depending on the selected mode, the display 

B8

 shows: set humidity in %, automatic 

start / shut-off time, current humidity in % (+/- 5 % in the range 30 % - 90 % relative 

humidity).

Setting the COMFORT operating mode

Button 

COMFORT B1

 serves to turn the COMFORT mode on and off (intelligent room 

humidity control mode). The On state is signalled by a lit indicator light above the 

COMFORT B1

 button.

In this mode, humidity is controlled automatically depending on the current room 

temperature. A specific humidity cannot be set.

Setting the continuous dehumidification mode

The 

CONT. B3

 is used to turn the continuous dehumidification mode on and off. The On 

state is signalled by a lit indicator light above the 

CONT. B3

 button.

In this mode, the appliance runs continuously until the condensate tank 

A3

 is completely 

full of condensate. A specific humidity cannot be set.

Setting the humidity

Use buttons 

/

 to set the required humidity in the range 35 % - 85 % RH (relative 

humidity). Each time a button is pressed, the value will increase or decrease by 5 %. The 

set humidity will be shown on the display 

B8

.

Setting fan speed

Button 

TURBO B4

 is used to set normal or high fan speed. The high speed fan setting is 

signalled by the indicator light above the 

TURBO B4

 button being lit.

For maximum dehumidification speed, set the fan to the high speed. If you need the fan 

to be more quiet or if humidity has declined, set the normal fan speed.

Setting an automatic start

While the appliance is turned off, press the 

TIMER B5

 button. The indicator light 

B9

 

will be lit, meaning that the appliance is set to the automatic start mode. Use buttons 

/

 to set the time after which the appliance will turn on automatically. You can set 

a time from 30 minutes to 24 hours, initially in 30-minute increments (up to 10 hours) 

and then in 1-hour increments. 

The set time is automatically saved to memory after approximately 5 seconds.

Automatic shut-off function

While the appliance is turned on, press the 

TIMER B5

 button. The indicator light 

B10

 

will be lit, meaning that the appliance is set to the automatic shut off mode. Use buttons 

/

 to set the time after which the appliance will turn off automatically. You can set 

a time from 30 minutes to 24 hours, initially in 30-minute increments (up to 10 hours) 

and then in 1-hour increments. 

The set time is automatically saved to memory after approximately 5 seconds and the 

display 

B8

 will show the set humidity.

Note: 

If you set both automatic start and shut off in the same selected mode, the 

B9

 and 

B10

 indicator lights will be lit.

If you turn the appliance on or off, while the automatic start or shut-off is 

set, the appliance will automatically cancel the start or shut-off function.

If the message "

P2

" appears on the display 

B8

, the automatic start / shut-off 

function will be cancelled.

Cleaning the filters

After approximately 250 hours of operation, the indicator light above button 

FILTER B2

 

will be lit, signalling that the filter requires cleaning.

Clean the filter according to the instructions in chapter "Cleaning and maintenance". 

Then press button 

FILTER B2

 to reset the operating time counter. The indicator light 

above the 

FILTER B2

 button will turn off.

Full condensate tank indicator

When the indicator light 

B11

 is lit on the control panel 

A1

, the condensate tank 

A3

 

is full and the condensate needs to be emptied out. The appliance will stop running. 

Empty out the condensate tank 

A3

 according to the instructions in chapter 

"Draining 

condensate into the tank"

. After installing the condensate tank 

A3

 the appliance will 

automatically start up again.

Summary of Contents for SDH 3020WH

Page 1: ...09 2019 1 Copyright 2019 Fast R a s EN Dehumidifier Translation of the original manual SDH 3020WH...

Page 2: ...ensions of the room correspond to the dimensions specified for its operation Theappliancemustbestoredinaroomwhereanopenflameisnotcontinuously in use e g running gas appliance or where there are source...

Page 3: ...n the appliance on or off always use the appropriate buttons on the control panel Do not turn off the appliance by disconnecting the power cord from the power socket Always turn off the appliance and...

Page 4: ...explosive substances Please contact an authorised service centre for repairs or maintenance of this appliance Do not connect the appliance into a power socket that is loose or damaged Do not use this...

Page 5: ...act a qualified electrician to install a properly grounded power socket Make sure that the power socket is easily accessible after the installation of the appliance Do not use extension cords or power...

Page 6: ...electrical shock Do not place the appliance in the vicinity of a heat source Plastic parts could melt and cause a fire If you register an unusual sound unpleasant odours or smoke coming out of the ap...

Page 7: ...be damaged by the effect of diffused chemicals and solvents in the air Never put fingers or other foreign objects into the grille or vents Be especially careful when children are present There is a ri...

Page 8: ...ccordance with the specific assessment of the association for this sector Maintenance tasks must be performed solely on the basis of the recommendations of this appliance s manufacturer Maintenance an...

Page 9: ...09 2019 9 Copyright 2019 Fast R a s 1 2 3 9 8 4 5 6 10 7 A On Off Full Auto defrost B C...

Page 10: ...wer plug into a power socket Turning on off Press button B7 to turn on the appliance In order to turn off the appliance press button B7 again The appliance will turn off automatically if the condensat...

Page 11: ...ater with a small addition of neutral detergent Make sure that water does not enter into the vents In the event that the grille A10 is only dusty a vacuum cleaner may be used to clean it Storage When...

Page 12: ...ergents containing chlorine must be excluded since chlorine may react with the refrigerant and corrode copper pipes In the event of a suspected leak all open flames must be removed extinguished In the...

Page 13: ...et gross 17 18 2 kg Operating temperature 5 32 C Recommended room area 58 73 m2 The declared noise emission level of the appliance is 50 dB A which represents a level A of acoustic power with respect...