Storing the portable air conditioner

•  In order to dry it and to prevent the formation of moulds, leave the 

portable air conditioner running in a warm room in the fan mode for 
approximately 12 hours.

•  Disconnect the flexible hose 

B1

 and store it in a safe place out of the 

reach of children.

•  Drain all the condensate from the condensate tank – see chapter 

Condensate drain outlet

”.

•  Clean the air filters and reinstall them. Wipe the outer case of the 

portable air conditioner. Remove the batteries from the remote control.

•  Store the air conditioner in a cool, dry and dark location.

Condensate drain outlet

•  If the water level inside the condensate tank reaches a predetermined 

level, the portable air conditioner will show “Ft” (full condensate 
tank) on the display 

C6

. In order to drain the condensate from the air 

conditioner, proceed as follows: 

1. 

 Disconnect the power plug from the power socket.

2.   Carefully re-locate the portable air conditioner to a location where 

the water may be drained.

3.   Underneath the drain outlet 

A11

, place a container into which the 

condensate will flow. Carefully remove the plug of the drain outlet 

A11

. Connect the drain hose 

B6

 and allow the condensate to flow 

out.

4.   Once the condensate tank is empty (condensate has stopped 

flowing), disconnect the drain hose 

B6

 and put the plug back into the 

drain outlet 

A11

.

 5.   Insert the power plug into a power socket and turn on the portable air 

conditioner.

•  If you need to ensure the condensate to be continuously drained from 

the portable air conditioner, it is possible to connect the drain hose 

B6

 

to a waste water drain. Proceed as follows:

1. 

 Disconnect the power plug from the power socket.

2.   Remove the plug of the top drain outlet 

A8

. Connect the drain 

hose 

B6

. If the length of the drain hose 

B6

 is insufficient, then it is 

necessary to purchase a longer hose of the same type. Never extend 
the length of the drain hose 

B6

 using extensions.

3.   Connect the end of the drain hose 

B6

 to the waste water drain.

4.   Insert the power plug into a power socket and turn on the portable air 

conditioner.

Note: 

The drain hose 

B6

 should be installed at the same height or 

lower than the top drain outlet 

A8

. Otherwise, the condensate 

will not be properly drained from the condensate tank.

Putting into operation again

•  Check that the power cord and plug are not damaged and that the 

air filters are clean. Insert a new set of batteries into the remote 
control. Proceed according to the instructions in section “Inserting and 
replacing batteries”. Install the portable air conditioner according to 
the instructions contained in the preceding part of this user’s manual 
“Installation”.

TROUBLESHOOTING
Error messages

Shown on 

the display

Meaning

Solution

Low 
temperature

The portable air conditioner has 
a system that prevents freezing at very 
low temperatures.
The air conditioner will start again once 
the internal system is defrosted.

Defect of the 
heat sensor

Contact an authorised service centre.

Full 
condensate 
tank

Empty the condensate tank. Proceed 
according to the instructions in section 
"

Condensate drain outlet

" described 

previously in this user's manual.

Note: 

In the event that one of the aforementioned faults occurs, 
turn off the portable air conditioner and check for the cause of 
the fault. Turn it on again, and if the fault reoccurs, turn it off, 
disconnect the power cord from the power socket and contact 
the manufacturer, an authorised service centre or a person with 
relevant qualifications and have the unit repaired.

Troubleshooting

•  Before contacting an authorised service centre, please check the 

appliance according to the following instructions:

Problem

Possible cause

Remedy

The portable air 
conditioner did 
not turn on.

There is no current in 
the power socket.

Engage the 
circuit breaker or, 
alternatively, try 
a different power 
socket.

The power plug is not 
inserted in a power 
socket.

Connect the power 
plug to the power 
socket.

The internal safety fuse 
is disengaged.

Wait 30 minutes, and 
if the problem persists, 
please contact an 
authorised service 
centre.

The portable air 
conditioner runs 
only for a short 
time.

The flexible air 
exhaust hose 

B1

 is 

not connected or it is 
blocked.

Turn off the air 
conditioner, disconnect 
the hose, check that 
it is not blocked and 
reconnect the hose.

Air inlets 

A7

 and 

A9

 are 

blocked.

Remove the obstacles 
preventing air supply to 
the inlets.

The portable air 
conditioner is on, 
but is not cooling.

The windows and doors 
of the room are open.

Make sure that all 
doors and windows are 
closed.

There are heat sources 
inside the room.

If possible remove 
these heat sources.

The flexible air 
exhaust hose 

B1

 is not 

connected.

Attach the flexible 
hose 

B1

.

The room area is too 
large.

Perform a double-
check of the cooled 
area.

An unpleasant 
odour is sensed 
while it is running.

The air filters are 
clogged with dirt and 
dust or animal fur.

Turn off the air 
conditioner and clean 
the filters according 
to the provided 
instructions.

The portable 
air conditioner 
turns off approx. 
3 minutes after 
it is turned on 
again.

Then 
compressor's safety 
fuse is protecting the 
air conditioner against 
damage if turned on 
sooner than after 3 
minutes.

Wait several minutes 
and then turn the air 
conditioner on again.

An error message 
appeared on the 
display 

C1

.

Proceed according 
to the instructions 
in section "

Error 

messages

".

Summary of Contents for SAC MT9030C

Page 1: ...EN PORTABLE AIR CONDITIONER WI FI Translation of the original manual SAC MT9030C SAC MT9031C...

Page 2: ...SAC MT9030C SAC MT9031C...

Page 3: ...A 1 2 3 4 5 6 8 9 7 10 11 B 1 2 3 4 5...

Page 4: ...C 2 3 4 5 6 W 7 8 9 10 11 12 13 D 1 4 2 7 5 6 3 8 9 10 E...

Page 5: ...must be adhered to Incorrect use as a result of not adhering to instructions may cause death injuries or damage This appliance may be used by children 8 years of age and older and by persons with phy...

Page 6: ...e g running gas appliance or where there are not sources of ignition e g running electrical heating element Before connecting the appliance to a power socket check that the rated voltage on its rating...

Page 7: ...that the appliance is correctly assembled according to the instructions in this user s manual Do not touch the appliance with wet or damp hands This applies especially when it is connected to a power...

Page 8: ...check that all the condensate has been drained After transporting it wait at least 1 hour before using the appliance Do not use the appliance if it is not working correctly if it has been damaged or h...

Page 9: ...r its power supply DO NOT CONNECT the unit to a power socket to which other electrical appliances are already connected The incorrect selection of an electrical power supply may result in a fire or in...

Page 10: ...Warning Fire hazard SPECIFIC INFORMATION FOR APPLIANCES USING REFRIGERANT GAS R290 Carefully study any warnings CAUTION For defrosting and cleaning do not use any other tools than those recommended by...

Page 11: ...ored in such a way as to prevent mechanical failure Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organisation that ensures...

Page 12: ...le air conditioner in a room with high humidity e g laundry Note Do not use the portable air conditioner to cool a room where computer servers etc are located Installation adjustment maintenance and r...

Page 13: ...tomatically If button TIMER C12 or POWER C8 are pressed after the automatic start is set then this setting will automatically be cancelled 2 Automatic shut off function When the portable air condition...

Page 14: ...ours and one hour intervals until 24 hours Press button D4 once to confirm the setting The set time will appear on the display D1 and symbol will remain lit Once the set time elapses the portable air...

Page 15: ...ioner according to the instructions contained in the preceding part of this user s manual Installation TROUBLESHOOTING Error messages Shown on the display Meaning Solution Low temperature The portable...

Page 16: ...ced in the event that it is used outside the above described operating temperature range We reserve the right to change text and technical specifications INSTRUCTIONS AND INFORMATION REGARDING THE DIS...

Page 17: ...FAST R a s U Sanitasu 1621 CZ 251 01 any www sencor eu...

Reviews: