Sencor SAC MT9030C Translation Of The Original Manual Download Page 14

- 10 -

Revision 12/2021

 Copyright © 2021, Fast ČR, a.s.

temperature. You can set the temperature in the range from 18 to 
32 °C.

•  Use button 

FAN D9

 to set the fan speed. Repeatedly press button 

FAN D9 

to switch the speed in the following order: High (high speed) – 

Medium (medium speed) – Low (low speed) – Auto (automatic speed). 
Each time the button is pressed, the arrow at the speed bar on the 
display 

D1

 will switch.

2. Fan mode

•  Repeatedly press button 

MODE D3

 until the arrow on the display 

D1

 

stops at symbol  .

•  Use button 

FAN D9

 to set the fan speed. Repeatedly press button 

FAN D9 

to switch the speed in the following order: High (high speed) 

– Medium (medium speed) – Low (low speed). Each time the button is 
pressed, the arrow at the speed bar on the display 

D1

 will switch.

Note: 

In the fan mode, it is not possible to set the temperature, 
therefore no temperature information will be shown on the 
display 

D1

.

3. Dehumidification mode

•  Repeatedly press button 

MODE D3

 until the arrow on the display 

D1

 

stops at symbol  . “dH” is shown on the display 

D1

.

•  It is not possible to change the fan speed in the dehumidification 

mode.

4. Automatic mode

•  If you select an automatic mode, the portable air conditioner will 

automatically select an operating mode based on the temperature in 
the room.

•  Repeatedly press button 

MODE D3

 until the arrow on the display 

D1

 

stops at symbol  .

•  Use button 

FAN D9

 to set the fan speed. Repeatedly press button 

FAN D9

 to switch the speed in the following order: High (high speed) – 

Medium (medium speed) – Low (low speed) – Auto (automatic speed). 
Each time the button is pressed, the arrow at the speed bar on the 
display 

D1

 will switch.

•  The portable air conditioner will start in the fan mode, when the 

temperature in the room is less than 23 °C, and in the cooling mode 
when the temperature in the room is higher than 23 °C.

Functions of the portable air conditioner
1.  Sleep function

•  The sleep function is used to reduce overnight power consumption, 

when a constant temperature is not necessary.

•  Selecting an operating mode – cooling – see previous part of the 

user’s manual.

•  Press button 

D5

, symbol 

 will appear on the display 

D1

. The 

portable air conditioner will run in the last selected mode. 

•  For the cooling mode, within two hours, the temperature will increase 

by 2 °C. This new temperature will be maintained for a period of 6 
hours and then the portable air conditioner will turn itself off.

•  The sleep function can be cancelled at any time by pressing button 

D5

D3

 or 

D9

.

•  The sleep function cannot be set in the fan and dehumidification 

modes.

2. Automatic start and shut-off function
Automatic start

•  The automatic start function makes it possible to set a time after which 

the portable air conditioner will start automatically.

•  Start the portable air conditioner by pressing button 

D1

. Using button 

D3

, select the operating mode in which you wish to turn on the 

portable air conditioner. Use buttons 

/

 

D7

 and 

D8

 to set the 

desired temperature and use button 

D9

 to select a fan speed as 

required. Turn off the portable air conditioner using button 

D1

.

•  Press button 

D4

 twice, the time and symbol 

 will appear on 

the display 

D1

. Use buttons 

/

 

D7

 and 

D8

 to set a time after which 

the portable air conditioner will automatically start. The automatic 
start time can be set in the range between 30 minutes and 24 hours 

(set in 30 minute intervals until 10 hours, and one hour intervals until 
24 hours).

•  Press button 

D4

 once to confirm the setting. The set time will appear 

on the display 

D1

 and symbol 

 will remain lit.

•  Once the set time elapses, the portable air conditioner will start 

automatically. If button 

D4

 or 

D2

 are pressed after the automatic start 

is set, then this setting will automatically be cancelled.

Automatic shut-off

•  The automatic shut-off function makes it possible to set a time after 

which the portable air conditioner will shut off automatically.

•  While the portable air conditioner is turned on, press button 

D4

 once. 

The time and symbol 

 will be shown on the display 

D1

.

•  Use buttons 

/

 

D7

 and 

D8

 to set a time after which the portable 

air conditioner will automatically turn off. The automatic shut-off time 
can be set in the range between 30 minutes and 24 hours (set in 30 
minute intervals until 10 hours, and one hour intervals until 24 hours).

•  Press button 

D4

 once to confirm the setting. The set time will appear 

on the display 

D1

 and symbol 

 will remain lit.

•  Once the set time elapses, the portable air conditioner will shut off 

automatically. If button 

D4

 or 

D2

 are pressed after the automatic shut-

off is set, then this setting will automatically be cancelled.

3. Flap angle function

•  Button 

D7

 can be used to select either left or right air flow. Press 

button 

D7

 once, an arrow and symbol 

 will appear on the display 

D1

. Pressing button 

D7

 will cause the arrow to disappear and the 

function to be cancelled.

Changing temperature units

•  While the air conditioner is in stand-by mode, press button 

D10

 to 

toggle the temperature units from °C to °F and vice versa.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

MAINTENANCE AND CLEANING

•  Before cleaning the portable air conditioner, turn it off and wait a few 

minutes, and then pull the power cord out of the power socket.

Cleaning the air filters

•  If the portable air conditioner is used regularly, it is necessary to 

clean the air filters at least once every 14 days to avoid the fan 
from becoming clogged with dust. Based on the model of your air 
conditioning unit, clean the following filters:

 

Clean both the air filter located behind the removable protective 
grille of the top air inlet 

A7

, as well as the air filter located behind 

the removable grille of the bottom air inlet 

A9

.

•  Carefully remove the protective grille and take out the respective 

filters. To remove the dust, use a vacuum cleaner. In the event of 
greater soiling, wash the filter by hand in a solution of lukewarm water 
(max. 40 °C) and neutral detergent. Then thoroughly rinse it under 
running water and allow it to dry naturally. Do not dry it in a clothes 
dryer or in direct sunlight. Once the filter is dry, you can install it back 
in its place.

Note: 

Do not use a portable air conditioner without the air filters 
properly installed and do not use it with wet or damp air filters.

•  The water collection (condensation) tank must be drained immediately 

when the code “Ft” appears on the display 

C1

 and also before this 

appliance is stored in order to prevent the formation of moulds.

•  In households with pets, it is necessary to wipe the grille regularly to 

prevent it from becoming clogged by animal fur.

Cleaning the outer case

•  To clean the outer case, use a soft wiping cloth dipped in a solution of 

lukewarm water and neutral detergent. Then wipe the surface dry.

•  When cleaning it, do not spray the portable air conditioner with water 

or any other liquid, do not pour water on it or submerge it in water or in 
any other liquid.

•  Do not use abrasive cleaning products, solvents, petrol, etc. for 

cleaning.

Summary of Contents for SAC MT9030C

Page 1: ...EN PORTABLE AIR CONDITIONER WI FI Translation of the original manual SAC MT9030C SAC MT9031C...

Page 2: ...SAC MT9030C SAC MT9031C...

Page 3: ...A 1 2 3 4 5 6 8 9 7 10 11 B 1 2 3 4 5...

Page 4: ...C 2 3 4 5 6 W 7 8 9 10 11 12 13 D 1 4 2 7 5 6 3 8 9 10 E...

Page 5: ...must be adhered to Incorrect use as a result of not adhering to instructions may cause death injuries or damage This appliance may be used by children 8 years of age and older and by persons with phy...

Page 6: ...e g running gas appliance or where there are not sources of ignition e g running electrical heating element Before connecting the appliance to a power socket check that the rated voltage on its rating...

Page 7: ...that the appliance is correctly assembled according to the instructions in this user s manual Do not touch the appliance with wet or damp hands This applies especially when it is connected to a power...

Page 8: ...check that all the condensate has been drained After transporting it wait at least 1 hour before using the appliance Do not use the appliance if it is not working correctly if it has been damaged or h...

Page 9: ...r its power supply DO NOT CONNECT the unit to a power socket to which other electrical appliances are already connected The incorrect selection of an electrical power supply may result in a fire or in...

Page 10: ...Warning Fire hazard SPECIFIC INFORMATION FOR APPLIANCES USING REFRIGERANT GAS R290 Carefully study any warnings CAUTION For defrosting and cleaning do not use any other tools than those recommended by...

Page 11: ...ored in such a way as to prevent mechanical failure Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organisation that ensures...

Page 12: ...le air conditioner in a room with high humidity e g laundry Note Do not use the portable air conditioner to cool a room where computer servers etc are located Installation adjustment maintenance and r...

Page 13: ...tomatically If button TIMER C12 or POWER C8 are pressed after the automatic start is set then this setting will automatically be cancelled 2 Automatic shut off function When the portable air condition...

Page 14: ...ours and one hour intervals until 24 hours Press button D4 once to confirm the setting The set time will appear on the display D1 and symbol will remain lit Once the set time elapses the portable air...

Page 15: ...ioner according to the instructions contained in the preceding part of this user s manual Installation TROUBLESHOOTING Error messages Shown on the display Meaning Solution Low temperature The portable...

Page 16: ...ced in the event that it is used outside the above described operating temperature range We reserve the right to change text and technical specifications INSTRUCTIONS AND INFORMATION REGARDING THE DIS...